Arama Sonuçları..

Toplam 18 kayıt bulundu.
NK-201 D. B Bracket Removing Plier

NK-201 D. B Bracket Removing Plier

Ideal for removing ceramic and stainless steel brackets. The tips wedge between edge of bracket and tooth surface and remove it with ease. Completely lip safe.

http://www.eksenmedikal.com.tr/nk-201-d-b-bracket-removing-plier

In-Ovation C - Esthetics without Compromise

In-Ovation C - Esthetics without Compromise

The In-Ovation C self-ligating bracket is made from ceramic material that compares to the strength and performance of metal.  A highly esthetic self-ligating bracket made from a special ceramic material with a rhodium processed clip for enhanced esthetics. The natural color of In-Ovation C makes the bracket a perfect fit for patients concerned about esthetics, while delivering functionality comparable to metal brackets.   THE POWER OF INTERACTIVE™ CONTROL FROM START TO FINISH In-Ovation C provides you with the ability to start and effectively finish your treatment in one, simple system. Using the technique of your choice, In-Ovation C enables you to maintain the precise degree of control that you need for each phase of your patient’s treatment. In-Ovation C’s revolutionary Interactive™ technology means you can choose the degree of engagement between the bracket and wire. In-Ovation C can be passive for leveling and aligning, expressive where control is realized and free-sliding is maintained, or active for controlled, optimal finishing. The choice is yours – a benefit not found in “passive only” brackets. INTERACTIVE CONTROL Passive Phase – Small, round wires slide freely, initiating the tooth movement process as the archwire gently levels the teeth and coaxes them into alignment. Expressive Phase – Square or rectangular wires are gently seated into the base of the slot without contacting the clip. Programming is expressed, rotations are corrected and space closures are completed. Active Phase – Rectangular archwires extend beyond the slot to fully engage the clip, providing the active control necessary for functional finishing, uprighting of the roots and adjusting the torque.   Practice Advantages In-Ovation C provides a great way to optimize your practice and expand treatment options. Studies consistently show that self-ligating brackets significantly lower frictional forces; offer faster, easier archwire changes; increase appointment intervals; and shorten patient treatment time. In-Ovation C is easy for doctors and staff to use. Designed for reliable performance, the bracket’s 100% mechanical lock base ensures reliable bonding, debonding and the ability to rebond. A specially designed interactive, Coballoy spring clip provides excellent    Patient Advantages Superb esthetics provide the confidence your patients will love Less chairtime during visits Longer intervals between appointments Excellent results Improved oral hygiene   The Art of Orthodontic Excellence Transluscent Ceramic Construction In-Ovation C brackets are manufactured from a high-tech ceramic that combines excellent translucency with strength and performance similar to that of steel. Reliable Mechanical Bonding In-Ovation C employs a proprietary process to form strong, undercut bonding nubs on the bottom of the bracket base. These provide excellent anchoring points for the adhesive, resulting in a bond that is 100% mechanical and debonds easily after treatment. Straight Wire Technology A true straight wire appliance is one in which all the brackets have been designed to guide teeth into their desired positions with a preformed wire. In-Ovation is a true straight wire appliance that features: Compound Contour Base Torque in the Base Programmed In-Out Control Level Slot Alignment True Twin Design Occlusal and gingival twin tie wings offer an optimal mesial, distal span for achieving superior rotation control. The elimination of the elastomeric ligatures increases your inter-bracket distance. Spring Clip The self-ligating clip extends fully through a vertical channel in the bracket body, enhancing the structural integrity of the clip. A unique rhodium treatment process provides a low-sheen surface for reduced visibility and enhanced aesthetics.   Easy Opening and Closing The clip opens easily when pressure is applied occlusally to the gingival sphere using the Engage-C.  This is the primary method for opening and closing the clip is the gingival sphere. If unable to access the gingival sphere you can also utilize the Opin notch on the facial surface of the clip applying gentle pressure occulsally with amini scaler. The clip can be closed with aninstrument or simple finger pressure  on the incisal curve.   Triple Chamfered Slot Walls Slot walls are beveled outward, facilitating wire engagement and reducing the chance of the archwire binding or crimping. Disto–Gingival Dimple A color-code on the disto-gingival tie wing provides immediate identification of the tooth for which the bracket is intended. A matching colored removable site gauge is also in the slot for position orientation. Smooth Swept Tie Wings Smooth, swept tie wings help to reduce occlusal interference while increasing patient comfort. Adequate undercuts allow easy anchoring for elastic chains or the fastening of color ties at the patient’s request.    

http://www.eksenmedikal.com.tr/in-ovation-c-esthetics-without-compromise

NeoSentalloy - Square or Rectangluar

NeoSentalloy - Square or Rectangluar

Intermediate archwire with body heat activation and true superelasticity with near constant forces. Also available with IONGUARD. Neo-Sentalloy is part of the Sentalloy wire family sharing the same properties designed to deliver a gentle, light continuous force to mitigate periodontal stress. UNIQUE PROPERTIES OF SENTALLOY SUPERELASTIC WIRES Body Heat Activation - At room temperature, Sentalloy wires are soft, pliable, and easy to engage. Once warmed to body temperature the wire gently and predictably guides the teeth to the present arch form. Superelasticity - Even when severely malposed, Sentalloy continues to exert its gentle, near constant forces as the tooth moves. Shape Memory Effect - Sentalloy will take displacements up to 90 degrees without deforming. Its overwhelming desire to return to its original shape actually promotes tooth movement with fewer 0wire changes and fewer patient visits. IONGUARD - IONGUARD is not a coating; it is a fundamental change in the wire’s surface. Without changing the wire’s dimensions, or altering any of the wire’s unique superelastic properties, the process produces sliding mechanics comparable to stainless steel, while sealing the occlusal surface to reduce nickel leaching and breakage.  

http://www.eksenmedikal.com.tr/neosentalloy-square-or-rectangluar

High Esthetic Archwires

High Esthetic Archwires

According to a recent patient survey by the American Journal of Orthodontics and Dentofacial Orthopedics, ceramic appliances with clear or white wires are rated consistently higher over their metal counterparts in terms of esthetics. This is a di­erence patients are willing to pay several hundred dollars for.  Crafted by a unique rhodium process, our High Esthetic  archwires have a low-reflectivity surface for a soft, frosted appearance delivering the same outstanding properties and performance as their standard counterparts.

http://www.eksenmedikal.com.tr/high-esthetic-archwires

Saturn™ Molar Bands - Mandibular 1st & 2nd Molar

Saturn™ Molar Bands - Mandibular 1st & 2nd Molar

Saturn™ bands are Ormco** size compatible.Precision-shaped tooth anatomy for a tight, secure fit with excellent retention. Our distinct right and left anatomy is completely proportioned in all planes and for each band size.Stainless steel that exhibits properties of "hardness" for strength to avoid wall collapse when fitting, yet is malleable enough for "snap" fitting that requires little or no burnishing.Increased buccal height for greater flexibility in the placement and positioning of buccal tubes and lingual attachments.Permanently etched using an Electro Chemical Etching process for easy permanent identification. Interiors are micro-etched to provide a rough ended surface for increased bond strength.30 upper and lower sizes graduated in even, closely spaced increments for improved fit.**G&H® is in no way affiliated with Ormco Corporation

http://www.eksenmedikal.com.tr/saturn-molar-bands-mandibular-1st-2nd-molar

MICROETCHER™ IIA

MICROETCHER™ IIA

The MicroEtcher IIA is recognized as one of the most valuable tools for dentistry. The MicroEtcher provides precise surface micro-roughening, improving bond strength up to 400%. Surface area and surface reactivity is dramatically increased for maximum bond. Sandblasting is fast and easy with most surface roughening procedures requiring only a few seconds. It offers all stainless construction and replaceable carbide tip. Now with a permanently affixed jar lid and spill resistant abrasive filter.Features:– Etching all metals, composites & amalgam for maximum bond strength– Intraoral porcelain repair– Pit & fissure prep– Cleaning darked grooves to reveal decay– Prepping incipient lesions and minor Class I & V– Debriding bur preps for best esthetics & bonds

http://www.eksenmedikal.com.tr/microetcher-iia

BioForce

BioForce

BioForce - Square or Rectangluar   Optimally biological forces begin at approximately 80 grams of force at the anteriors, and gradually increase to approximately 300 grams of force in the molars. Also available with IONGUARD. Optimal Tooth Movement and Ideal Biological Forces As this chart shows, the optimal force needed to move anteriors is not the same as the optimal force needed to move molars. If a force is designed to move anteriors, it is too light to move molars. If a force is great enough to move molars, the force is too strong - traumatically strong - for anteriors. Other wires offer one force at a time, requiring at least two or three wire changes to achieve the desired movement. BioForce exhibits low forces at the anterior, gradually increases force in the bicuspids, and again in the molars. Each tooth receives the optimal biological force necessary to move specific teeth in one wire. Anterior Region of arch form has the lowest heat-activated force, as anterior teeth have the lightest roots. The Bicuspid Region of the arch maintains a slightly greater heat-activated force to move larger rooted bicuspids. The Posterior Region of the arch form has the greatest heat-activated force within the archwire for moving thestrong-rooted molars. BioForce also shares the properties of all Sentalloy wires and is designed to deliver a gentle, light continuous force to mitigate periodontal stress. UNIQUE PROPERTIES OF SENTALLOY SUPERELASTIC WIRES Body Heat Activation At room temperature, Sentalloy wires are soft, pliable, and easy to engage. Once warmed to body temperature the wire gently and predictably guides the teeth to the present arch form. Superelasticity Even when severely malposed, Sentalloy continues to exert its gentle, near constant forces as the tooth moves. Shape Memory Effect Sentalloy will take displacements up to 90 degrees without deforming. Its overwhelming desire to return to its original shape actually promotes tooth movement with fewer 0wire changes and fewer patient visits. IONGUARD - IONGUARD is not a coating; it is a fundamental change in the wire’s surface. Without changing the wire’s dimensions, or altering any of the wire’s unique superelastic properties, the process produces sliding mechanics comparable to stainless steel, while sealing the occlusal surface to reduce nickel leaching and breakage.

http://www.eksenmedikal.com.tr/bioforce-square-or-rectangluar

NK-207 Direct Bond Removing Plier, Straight

NK-207 Direct Bond Removing Plier, Straight

Ideal for removing ceramic and stainless steel brackets. The tips wedge between edge of bracket and tooth surface and remove it with ease. Completely lip safe.

http://www.eksenmedikal.com.tr/nk-207-direct-bond-removing-plier-straight

Saturn™ Molar Bands - Maxillary 1st & 2nd Molar

Saturn™ Molar Bands - Maxillary 1st & 2nd Molar

Saturn™ bands are Ormco** size compatible.Precision-shaped tooth anatomy for a tight, secure fit with excellent retention. Our distinct right and left anatomy is completely proportioned in all planes and for each band size.Stainless steel that exhibits properties of "hardness" for strength to avoid wall collapse when fitting, yet is malleable enough for "snap" fitting that requires little or no burnishing.Increased buccal height for greater flexibility in the placement and positioning of buccal tubes and lingual attachments.Permanently etched using an Electro Chemical Etching process for easy permanent identification. Interiors are micro-etched to provide a rough ended surface for increased bond strength.30 upper and lower sizes graduated in even, closely spaced increments for improved fit.**G&H® is in no way affiliated with Ormco Corporation

http://www.eksenmedikal.com.tr/saturn-molar-bands-maxillary-1st-2nd-molar

In-Ovation® R - The Original

In-Ovation® R - The Original

In-Ovation R has been recognized as an industry leader for over a decade. Thousands of clinicians worldwide have trusted In-Ovation to treat their patients. The precision and quality built into these brackets offers repeatable success, practice efficiencies and beautiful results every time. See how far In-Ovation R can take you, your patients and your practice.   In-Ovation Means Interactive In-Ovation R provides you with the ability to start and effectively finish your treatment with one, simple system. Using the technique of your choice, In-Ovation R enables you to maintain the precise degree of control that you need for each phase of your patient’s treatment. In-Ovation R’s unique Interactive technology means you can choose the degree of engagement between the bracket and wire. It can be passive for leveling and aligning, expressive where control is realized and free-sliding is maintained, or active for controlled, optimal finishing. Passive Phase   Expressive Phase   Active Phase Small, round wires slide freely, initiating the tooth movement process as the archwire gently levels the teeth and coaxes them into alignment.   Square or rectangular wires are gently seated into the base of the slot without contacting the clip. Programming is expressed, rotations are corrected and space closures are completed.   Rectangular archwires extend beyond the slot to fully engage the clip, providing the active control necessary for functional finishing, uprighting of the roots and adjusting the torque.   Practice Advantages Not all self-ligating brackets are created equal. In-Ovation R brackets were created to optimize the treatment process with precision engineering and true straight wire design. The In-Ovation orthodontic systems are the result of a keen understanding of human physiology and orthodontic engineering. The compound contoured base of the In-Ovation R bracket is designed to provide a precise anatomical fit across the enamel surface of the tooth. The smooth swept tie-wings are engineered to minimize occlusal interference in order to increase patient comfort. In addition, the chamfered archwire slot is designed to reduce chair time by facilitating wire engagement and reducing the chance of archwire binding or crimping. This dedication to quality and attention to detail is infused into every product that carries the In-Ovation name. Patient Advantages Today more than ever, patients are doing their part to better understand the options available to them. Savvy practices have come to recognize this as an opportunity, enabling you to offer the benefits of self-ligation as an adjunct to your talent, technique and reputation. In providing a self-ligating option, you’ll be able to offer your patients less chair time, fewer appointments and a cleaner, more esthetic appearance. In doing so, you’ll be able to create a perceived (and potentially significant) point of differentiation between your practice and the other competing practices in the area.   In-Ovation R Dedication to Detail True Twin Design – Occlusal and gingival twin tie-wings offer an optimal mesial, distal span for achieving superior rotation control. The elimination of the elastomeric ligatures increase your inter-bracket distance. Spring Clip – The self-ligating clip extends fully through the vertical channel in the bracket body, enhancing the structural integrity of the clip. Base Design – The exclusive patented Palmer Notation laser etched into the mesh facilitates bracket management with a ready reference of the quadrant, tooth and prescription.An 80 gauge single mesh, compound contoured base provides a precise anatomical fit.  Full Slot Slip Coverage – The In-Ovation R clip provides full coverage across the entire slot for superior rotational control. This allows the clip to interact with the wire both on the mesial and distal, as needed, without the need for auxiliaries. Straight Wire Technology In-Ovation is a completely adjusted true straight wire appliance system that positions teeth at all four dimensions: in/out, angulations, torque, and overcorrection. With this completely adjusted four dimensional appliance system you will need no offset bends in the archwires to obtain an optimal finish in most cases (if the brackets are optimally positioned on teeth). In order to be considered a completely four-dimensional appliance, the bracket must contain: Compound contour base Torque in base Proper in/out and anti-rotation Level slot alignment at the conclusion of appliance therapy Easy Open Clip – The clip opens easily when pressure is applied occlusally to the v-notched clip at the gingival side of the bracket, using the engage R or similar instrument. The clip can be closed with an instrument or simple finger pressure on the incisal curve. Triple Chamfered Slot Walls – Slot walls are beveled outward, facilitating wire engagement and reducing the chance of the archwire binding or crimping. Vertical Scribe Line – A scribe line on the bracket face aids positioning by providing a convenient reference for orienting the center line of the bracket with the facial axis of the clinical crown (FACC). Smooth Swept Tie-Wings –Help to reduce occlusal interference while increasing patient comfort. Adequate undercuts allow easy anchoring for elastic chains or the fastening of color ties at the patient’s request.

http://www.eksenmedikal.com.tr/in-ovation-r-the-original

Saturn™ Bicuspid Bands - Maxillary & Mandibular

Saturn™ Bicuspid Bands - Maxillary & Mandibular

Saturn™ bands are Ormco** size compatible.   Precision-shaped tooth anatomy for a tight, secure fit with excellent retention. Our distinct right and left anatomy is completely proportioned in all planes and for each band size.Stainless steel that exhibits properties of "hardness" for strength to avoid wall collapse when fitting, yet is malleable enough for "snap" fitting that requires little or no burnishing.Increased buccal height for greater flexibility in the placement and positioning of buccal tubes and lingual attachments.Permanently etched using an Electro Chemical Etching process for easy permanent identification. Interiors are micro-etched to provide a rough ended surface for increased bond strength.24 upper and lower sizes graduated in even, closely spaced increments for improved fit.**G&H® is in no way affiliated with Ormco Corporation

http://www.eksenmedikal.com.tr/saturn-bicuspid-bands-maxillary-mandibular

PROTRACTION <b class=red>FACE</b> MASK

PROTRACTION FACE MASK

The adaptability of this Protraction Face Mask allows for directional force application by adjusting the elastics engagement bar to deliver protractive force in the desired plane. Fully adjustable forehead and chin rests allow for adaptation to most patient’s anatomical structure. The angle of traction is then determined by adjusting the elastics engagement bar to deliver horizontal, upward or downward forces as necessary.Includes Allen wrench and 3 sets of pads.

http://www.eksenmedikal.com.tr/protraction-face-mask

REVERSE PULL <b class=red>FACE</b> MASK SMALL-LARGE

REVERSE PULL FACE MASK SMALL-LARGE

The stainless steel frame is softened by hypo-allergenic chin and forehead pads to minimize irritation and maximize patient acceptance. Bilateral and bi-longitudinal adjust-ability allow for patient customization.Each mask also includes: 1 forehead pad, 2 chin pad and replacement screws.

http://www.eksenmedikal.com.tr/reverse-pull-face-mask-large

<b class=red>Face</b>bows - Standard

Facebows - Standard

Our high quality stainless steel .045 inner and .072 outer bows are laser welded together for maximum durability and comfort. Available in 5 inner bow sizes and 2 outer bow sizes. Medium outer bow is 12mm longer than the short outer bow.*Spans are measured from the distal of one bow loop to the distal of the other loop.Sold individually.

http://www.eksenmedikal.com.tr/facebows-standard

HEADGEAR STORAGE CASES

HEADGEAR STORAGE CASES

Headgear Storage Cases with Velcro® closures conveniently store facebow and headgear to protect and organize. Perfect size for any configuration. Approximately 5.75" x 9.5" (15cm x 24cm)5 per package.

http://www.eksenmedikal.com.tr/headgear-storage-cases

Alpha-Glaze® Sur<b class=red>face</b> Sealant

Alpha-Glaze® Surface Sealant

Alpha-Glaze® Surface Sealant is a fluoride containing light cure unfilled resin with low viscosity to be used as a finishing sealant for composites and resin cements. It is formulated to penetrate and seal the micro-cracks and surface imperfections that are created by the finishing procedures. It can also be used to treat the enamel surface prior to applying Orthodontic Appliances.

http://www.eksenmedikal.com.tr/alpha-glaze-surface-sealant

Alpha-Dent® Metal Conditioner

Alpha-Dent® Metal Conditioner

Alpha-Dent® Metal Conditioner is to be used as a primer for amalgam, gold or stainless steel. The conditioned metal surface will provide the optimal bonding surface for the adhesive.

http://www.eksenmedikal.com.tr/alpha-dent-metal-conditioner

G&amp;H G4™ Nickel Titanium Open Coil Springs

G&H G4™ Nickel Titanium Open Coil Springs

Open coil springs open and maintain space gently and efficiently in a convenient cut to length design.Choose from (3) 7" straight lengths or (1) 21" SpoolPrecision formed G4™ Nickel Titanium alloy into closed coil springs. G4™ Nickel Titaniam springs provide consistent force and remain active until the space is closed. Consistent force values and full recovery are both routinely achieved with G4™ Nickel Titanium. *Forces determined by compressing a 1" open coil spring. Wire Size I.D. Force Compressed 25% (.250") Compressed 50% (.500") .009" .030 Extra Light 95 g 225 g .010" .030 Light 120 g 260 g .010" .036 Medium Light 90 g 200 g .012" .030 Medium 220 g 480 g .012" .036 Medium Heavy 180 g 380 g .014" .030 Heavy 360 g 700 g .014" .036 Extra Heavy 270 g 560 g .010" .045 Facebow 50 g 120 g

http://www.eksenmedikal.com.tr/g-h-g4-nickel-titanium-open-coil-springs

 
3WTURK CMS v6.03WTURK CMS v6.0