Arama Sonuçları..

Toplam 34 kayıt bulundu.

678-207 Band Removing Pliers

678-207 Band Removing Pliers

LONG POSTERIOR BAND REMOVING PLIERS   The alignment of the tip and occlusal pad is well suited for posterior band removal.

http://www.eksenmedikal.com.tr/678-207

Stainless Steel - Ball <b class=red>Post</b> - Bioform III

Stainless Steel - Ball Post - Bioform III

Bioform III MBT* Tapered / Ideal** CompatibleOur exclusive XR1™ Ball Post archwires offer the comfort and retention of ball ends plus a bendable brass post.A G&H proprietary soldering technique ensures clean, strong and consistent joints. The 16x22 or 19x25 XR1™ stainless base wire is heat treated and stress relieved – increasing the resiliency of the wire to improve mechanics.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Posted Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Ideal is a trademark of Dentsply GAC Intl.  

http://www.eksenmedikal.com.tr/stainless-steel-ball-post-bioform-iii

Stainless Steel - Keyhole 2 Loop - Trueform™ I

Stainless Steel - Keyhole 2 Loop - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleLooped archwires offer excellent versatility for a variety of applications including anterior intrusion, space closure, elastic engagement, anterior retraction, etc.Looped archwires are offered in a range of sizes to accommodate most patients upper and lower arches, locating the loops between the lateral and cuspid. Manipulate anterior and posterior segments by activating the loops independently or in unison.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Looped Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco

http://www.eksenmedikal.com.tr/stainless-steel-keyhole-2-loop-trueform-i

V-CUT PHOTOGRAPHY RETRACTOR HI-HEAT 2PK

V-CUT PHOTOGRAPHY RETRACTOR HI-HEAT 2PK

Take intra-oral photos without and assistant. Patient can hold retractors. Elongated ends allow unrestricted access to anterior and posterior regions in the mouth. One side is for adults and the other is for children. Package of 2.

http://www.eksenmedikal.com.tr/liquid-etchant-for-tooth-preparation-1-9g-bottle

SWIVEL HEAD BRACKET POSITIONER

SWIVEL HEAD BRACKET POSITIONER

This stainless steel positioning device features four bracket height measurements: 3.5, 4.0, 4.5, and 5.0. Adjustable for use on both anterior and posterior teeth.Hinged tip adjustable to 45°. Works with .022 and .018 bracket systems.Autoclavable up to 370°F/188°C

http://www.eksenmedikal.com.tr/swivel-head-bracket-positioner

Stainless Steel - Ball <b class=red>Post</b> - Europa™ Form I

Stainless Steel - Ball Post - Europa™ Form I

Europa™ Form I MBT* Ovoid CompatibleOur exclusive XR1™ Ball Post archwires offer the comfort and retention of ball ends plus a bendable brass post.A G&H proprietary soldering technique ensures clean, strong and consistent joints. The 17x25 or 19x25 XR1™ stainless base wire is heat treated and stress relieved – increasing the resiliency of the wire to improve mechanics.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Posted Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is trademark of 3M Unitek

http://www.eksenmedikal.com.tr/stainless-steel-ball-post-europa-form-i

Stainless Steel - Keyhole 4 Loop - Trueform™ I

Stainless Steel - Keyhole 4 Loop - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleLooped archwires offer excellent versatility for a variety of applications including anterior intrusion, space closure, elastic engagement, anterior retraction, etc.Looped archwires are offered in a range of sizes to accommodate most patients upper and lower arches, locating the loops between the lateral and cuspid. Manipulate anterior and posterior segments by activating the loops independently or in unison.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Looped Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco

http://www.eksenmedikal.com.tr/stainless-steel-keyhole-4-loop-trueform-i

NEOSmile™ Tooth Positioner

NEOSmile™ Tooth Positioner

The NEOsmile™ is a preformed tooth positioner that will idealize the patient's finishing occlusion upon debanding. The NEOsmile™ will maintain a Class I ideal relationship and provide some buffering against TMJ related irritations. Each NEOsmile™ incorporates molded airholes for unencumbered breathing. Like a custom tooth positioner, the NEOsmile™ is seated on the upper arch posterior on one side and stretched to the opposite side. Then the patient can gently clench to fully occlude into the appliance.TYPICAL INDICATED APPLICATIONSModerate space closure, band spaces, minor to moderate diastema closure, 3-4° torque, 5-8° rotation, and minor to moderate uprighting can be achieved where space is available.Generalized spacing may be corrected by staging sizes of the NEOsmile™. When generalized spacing is present and NEOsmile™ is fitted to the patient, it is typically recommended to use a size smaller than the patient's measured size. Patients with moderate generalized spacing may require the use of two concurrent NEOsmile™ positioners in incrementally smaller sizes to achieve ideal results.SELECTING THE PROPER SIZEDetermine the patient size for the NEOsmile™ by measuring the millimeter span from distal of upper cuspid to distal of opposite cuspid along the incisal edges.Sold individuallyKit of 10 (includes 1 of 10 select sizes)  

http://www.eksenmedikal.com.tr/neosmile-tooth-positioner

E-529 Heavy Duty Cutter TC

E-529 Heavy Duty Cutter TC

    This instrument cuts up to 1.5 mm wire with ease due to its triple action design. Minimum Cutting Capacity: 0.36 mm Maximum Cutting Capacity: Wire up to 1.5 mm.

http://www.eksenmedikal.com.tr/e-529-heavy-duty-cutter-tc

NK-203 <b class=red>Post</b>erior Band Removing Plier, Long

NK-203 Posterior Band Removing Plier, Long

Will remove band with maximum patient comfort. The steel tip is in the middle of the pad for easy band removal using simple pressure

http://www.eksenmedikal.com.tr/nk-203-posterior-band-removing-plier-long

Stainless Steel - Ball <b class=red>Post</b> - Europa™ Form II

Stainless Steel - Ball Post - Europa™ Form II

Europa™ Form II Damon* CompatibleOur exclusive XR1™ Ball Post archwires offer the comfort and retention of ball ends plus a bendable brass post.A G&H proprietary soldering technique ensures clean, strong and consistent joints. The 16x25 or 19x25 XR1™ stainless base wire is heat treated and stress relieved – increasing the resiliency of the wire to improve mechanics.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Posted Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*G&H is in no way affiliated with or endorsed by Ormco Corp. or Dr. Dwight Damon

http://www.eksenmedikal.com.tr/stainless-steel-ball-post-europa-form-ii

Stainless Steel - T-Loop - Trueform™ I

Stainless Steel - T-Loop - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleLooped archwires offer excellent versatility for a variety of applications including anterior intrusion, space closure, elastic engagement, anterior retraction, etc.Looped archwires are offered in a range of sizes to accommodate most patients upper and lower arches, locating the loops between the lateral and cuspid. Manipulate anterior and posterior segments by activating the loops independently or in unison.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Looped Archwire Kit of 100 wires size distribution MM Sizing 24 26 28 30 32 34 36 38 40 42 44 46 Quantity 5 10 10 10 5 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco

http://www.eksenmedikal.com.tr/stainless-steel-t-loop-trueform-i

In-Ovation® mini - Small Imprint, Big Impact

In-Ovation® mini - Small Imprint, Big Impact

The  In-Ovation® mini bracket is the smallest self-ligating twin bracket we’ve ever produced. Designed, developed and manufactured using the latest in micro-engineering technology, In-Ovation mini raises the bar on low-profile performance. From the innovative clip design to the patented Interactive™ technology that offers unmatched precision and control—In-Ovation® mini gives you the power to finish every case with the utmost precision. And with a smaller than other competitive interactive brackets your patients will love the esthetics and comfort level. Innovation means doing more with less, and no bracket does more for you, your practice, and your patients, than the In-Ovation mini. It’s the bracket you’ve always wanted, from the company you’ve always trusted. Programmed for Versatility In-Ovation® mini is proud to offer you the versatility of both interactive and passive design in a single unified system. It puts unprecedented treatment options in your hands. Passive cuspids and bicuspids are available in the posterior for lower friction sliding mechanics. INTERACTIVE CONTROL Passive Phase – Small, round wires slide freely, initiating the tooth movement process as the archwire gently levels the teeth and coaxes them into alignment.       Expressive Phase – Square or rectangular wires are gently seated into the base of the slot without contacting the clip. Programming is expressed, rotations are corrected and space closures are completed.     Active Phase – Rectangular archwires extend beyond the slot to fully engage the clip, providing the active control necessary for functional finishing, uprighting of the roots and adjusting the torque.     Design Features Interactive Spring Clip Presents the utmost in control throughout treatment.   True Twin Design Four tie-wings with adequate undercuts and integrated body channel allow easy anchoring of elastic chains or use of color ties at the patient’s request. Base Design An 80 gauge single mesh, compound contoured base provides a precise anatomical fit. Exclusive Patented Standard Palmer Notation laser etched into the mesh facilitates bracket management with a ready reference of the quadrant, tooth and prescription. Full Slot Clip Coverage For rotational control that limits the need for auxiliaries. Facial Scribe Line Added to the In-Ovation mini for simplified placement. True Straight Wire Design A true straight wire appliance is one in which all the brackets have been designed to guide the teeth into their ideal position with a preformed wire. In-Ovation® mini is a true straight wire appliance that features a compound contour base, torque in the base, programmed in-out control and level slot alignment. Easy Open Clip Affords a frustration-free procedure. Disto-Gingival Dimple A color code on the disto-gingival tie-wing provides immediate identification of the tooth for which the bracket was designed. Triple Chamfered Slot Walls Ease of engagement, reducing the chance of the archwire binding or crimping. Smooth Swept Tie Wings Helps reduce occlusal interference while increasing patient comfort.

http://www.eksenmedikal.com.tr/in-ovation-mini-small-imprint-big-impact

BioForce

BioForce

BioForce - Square or Rectangluar   Optimally biological forces begin at approximately 80 grams of force at the anteriors, and gradually increase to approximately 300 grams of force in the molars. Also available with IONGUARD. Optimal Tooth Movement and Ideal Biological Forces As this chart shows, the optimal force needed to move anteriors is not the same as the optimal force needed to move molars. If a force is designed to move anteriors, it is too light to move molars. If a force is great enough to move molars, the force is too strong - traumatically strong - for anteriors. Other wires offer one force at a time, requiring at least two or three wire changes to achieve the desired movement. BioForce exhibits low forces at the anterior, gradually increases force in the bicuspids, and again in the molars. Each tooth receives the optimal biological force necessary to move specific teeth in one wire. Anterior Region of arch form has the lowest heat-activated force, as anterior teeth have the lightest roots. The Bicuspid Region of the arch maintains a slightly greater heat-activated force to move larger rooted bicuspids. The Posterior Region of the arch form has the greatest heat-activated force within the archwire for moving thestrong-rooted molars. BioForce also shares the properties of all Sentalloy wires and is designed to deliver a gentle, light continuous force to mitigate periodontal stress. UNIQUE PROPERTIES OF SENTALLOY SUPERELASTIC WIRES Body Heat Activation At room temperature, Sentalloy wires are soft, pliable, and easy to engage. Once warmed to body temperature the wire gently and predictably guides the teeth to the present arch form. Superelasticity Even when severely malposed, Sentalloy continues to exert its gentle, near constant forces as the tooth moves. Shape Memory Effect Sentalloy will take displacements up to 90 degrees without deforming. Its overwhelming desire to return to its original shape actually promotes tooth movement with fewer 0wire changes and fewer patient visits. IONGUARD - IONGUARD is not a coating; it is a fundamental change in the wire’s surface. Without changing the wire’s dimensions, or altering any of the wire’s unique superelastic properties, the process produces sliding mechanics comparable to stainless steel, while sealing the occlusal surface to reduce nickel leaching and breakage.

http://www.eksenmedikal.com.tr/bioforce-square-or-rectangluar


Stainless Steel - Ball <b class=red>Post</b> - Trueform™ I

Stainless Steel - Ball Post - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleOur exclusive XR1™ Ball Post archwires offer the comfort and retention of ball ends plus a bendable brass post.A G&H proprietary soldering technique ensures clean, strong and consistent joints. The 16x22 or 19x25 XR1™ stainless base wire is heat treated and stress relieved – increasing the resiliency of the wire to improve mechanics.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Posted Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco

http://www.eksenmedikal.com.tr/stainless-steel-ball-post-trueform-i

G4™ Nickel Titanium - Bioform III - G4orce™

G4™ Nickel Titanium - Bioform III - G4orce™

Bioform III MBT* Tapered / Ideal** CompatibleG4orce™ is a G4™ Nickel Titanium wire with 3 distinct zones offering progressive forces that increase from anterior to posterior. Light anterior force (100g), medium cuspid/bicuspid force (200g), and a heavy molar force (300g) when applied to a 19x25 wire.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-bioform-iii-g4orce

Brass <b class=red>Post</b>ed Wire

Brass Posted Wire

Our Posted archwires combine the resiliency of stainless steel archwire with the malleability of brass for easy directional bending of the post. Available in .018" x .025" and .019" x .025", pack of 10 wires.

http://www.eksenmedikal.com.tr/brass-posted-wire

Brass <b class=red>Post</b>ed Wire

Brass Posted Wire

Our Posted archwires combine the resiliency of stainless steel archwire with the malleability of brass for easy directional bending of the post. Available in .018" x .025" and .019" x .025", pack of 10 wires.

http://www.eksenmedikal.com.tr/brass-posted-wire-1


OPAL Crimpable Ball Hook

OPAL Crimpable Ball Hook

Precision manufactured split crimpable ball hooks offer reliable performance during treatment when elastics or extension springs are needed. Also provides an effective alternative to preposted arch wires. The ball hook may be crimped without removing the arch wire. Ball hook is straight and measures 5mm from base to ball. The straight hook may be bent in any direction. Fits round and rectangular wire sizes up to .021ʺ x .028ʺ.

http://www.eksenmedikal.com.tr/crimpable-ball-hook

Stainless Steel - Straight <b class=red>Post</b> - Europa™ Form I

Stainless Steel - Straight Post - Europa™ Form I

Europa™ Form I MBT* Ovoid CompatibleOur Posted Archwires facilitate retraction, Class II engagement, and segmented force application as desired.We hand processes each stainless archwire with .030" silver soldered brass posts. Sized in 2mm increments, upper archwires are available in 34 to 44 mm sizes, lower in 22 to 32mm. Posted Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is trademark of 3M Unitek

http://www.eksenmedikal.com.tr/stainless-steel-straight-post-europa-form-i

Accu-Force™ and Accu-Force™ G3 - An Economic NiTi Wire Option

Accu-Force™ and Accu-Force™ G3 - An Economic NiTi Wire Option

  These advanced superelastic and heat-activated archwires are available in round, square, and rectangular for all stages of treatment. Superelastic provides gentle, nearly constant forces. Shape memory effect provides an overwhelming desire to return to original shape. Heat activated are soft and pliable, easy to engage at room temperature, may be chilled for easier ligation. Optimal tooth movement and ideal biological forces in Accu-Force™ G3 wires. Accu-Force™ round is used as an initial archwire. The superelastic  NiTi wire provides near constant  forces during the leveling and  aligning stage of treatment. Accu-Force™ G3 - Sqaure or Rectangular is an advanced superelastic archwire for early to mid treatment. Accu-Force™ G3 starts with low, gentle forces for the anteriors, and increases force in the posterior, where it plateaus in the molar region, all in the same wire.

http://www.eksenmedikal.com.tr/accu-force-and-accu-force-g3-an-economic-niti-wire-option


Stainless Steel - Straight <b class=red>Post</b> - Europa™ Form II

Stainless Steel - Straight Post - Europa™ Form II

Europa™ Form II Damon* CompatibleOur Posted Archwires facilitate retraction, Class II engagement, and segmented force application as desired.We hand processes each stainless archwire with .030" silver soldered brass posts. Sized in 2mm increments, upper archwires are available in 34 to 44 mm sizes, lower in 22 to 32mm. Posted Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*G&H is in no way affiliated with or endorsed by Ormco Corp. or Dr. Dwight Damon

http://www.eksenmedikal.com.tr/stainless-steel-straight-post-europa-form-ii

NK-217 Ligature Cutter

NK-217 Ligature Cutter

  Provided with 7°cutting angle for easy access.  

http://www.eksenmedikal.com.tr/nk-217-ligature-cutter

Stainless Steel - Straight <b class=red>Post</b> - Trueform™ I

Stainless Steel - Straight Post - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleOur Posted Archwires facilitate retraction, Class II engagement, and segmented force application as desired.We hand processes each stainless archwire with .030" silver soldered brass posts. Sized in 2mm increments, upper archwires are available in 34 to 44 mm sizes, lower in 22 to 32mm. Posted Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco

http://www.eksenmedikal.com.tr/stainless-steel-straight-post-trueform-i

M5™ Copper Nickel Titanium - Reverse Curve III

M5™ Copper Nickel Titanium - Reverse Curve III

Reverse Curve III Straight Leg, identical to our Trueform™ I shape with moderate curve and no distal toe-in or posterior torque.A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-reverse-curve-iii

G4™ Nickel Titanium - Reverse Curve III

G4™ Nickel Titanium - Reverse Curve III

Reverse Curve III Straight Leg, identical to our Trueform™ I shape with moderate curve and no distal toe-in or posterior torque.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-reverse-curve-iii

G&amp;H BRASS SEPARATING WIRE

G&H BRASS SEPARATING WIRE

Brass Separating Wire is high quality corrosion resistant 60/40 brass for posterior separation prior to band placement.

http://www.eksenmedikal.com.tr/g-h-brass-separating-wire

G4™ Nickel Titanium - Trueform™ I - G4orce™

G4™ Nickel Titanium - Trueform™ I - G4orce™

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleG4orce™ is a G4™ Nickel Titanium wire with 3 distinct zones offering progressive forces that increase from anterior to posterior. Light anterior force (100g), medium cuspid/bicuspid force (200g), and a heavy molar force (300g) when applied to a 19x25 wire.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-trueform-i-g4orce

EVERSTICK LINGUAL RETAINER 2PK

EVERSTICK LINGUAL RETAINER 2PK

everStick® ORTHO incorporates a thousand glass fiber strands bound together with a pre-impregnated light cure adhesive that allows adaptation directly in the patient’s mouth. The integrated fiber bundle is both malleable and tacky – perfect characteristics for close adaptation and positive retention prior to curing. .030” (.75mm) passive diameter - flattens significantly during adaptation.   Ideal for many applications, including:Lingual upper and lower retentionDiastema retentionPosterior anchorageTrauma or periodontal splintingExtraction site maintenance   Kit includes: (2) 12cm strands   Difference between EverStick® Ortho and EverStick® A&O?   Answer: EverStick® A&O is .17mm thicker and contains more glass fibers than EverStick® Ortho.

http://www.eksenmedikal.com.tr/everstick-lingual-retainer-2pk

GAC Sentalloy® Closed Coil Springs

GAC Sentalloy® Closed Coil Springs

Closing spaces with closed Sentalloy coil springs brings exceptional results.   TWO DESIGNS ARE AVAILABLE: Two Eyelet Design: The initial length is 3mm unactivated (this does not include the eyelet lengths). These can be activated to 15mm without any deformation or change in force. No change in force will be seen as the coil contracts, reducing the space. To engage, slide over a molar hook and slowly stretch to the post on the cuspid bracket or a sliding hook on the archwire. Use a locking Mathieu plier on the widened platform of the eyelet. If you do not use the cuspid post, tie the archwire to the tooth you wish to move, slide on the sliding hook, then tie in the balance of the wire. Now engage the spring as above. For an eyelet with ligature wire, you have the option of hooking the eyelet on the molar, then activating the spring and tying it to the cuspid bracket with the .008” ligature wire. Should you wish to span an area greater than 15mm, measure the span first. Then place the coil on the molar hook and activate the coil 10mm. Tie the ligature wire to the bracket. 

http://www.eksenmedikal.com.tr/gac-sentalloy-closed-coil-springs

 
3WTURK CMS v6.03WTURK CMS v6.0