Arama Sonuçları..

Toplam 6 kayıt bulundu.
E-529 <b class=red>Heavy</b> Duty Cutter TC

E-529 Heavy Duty Cutter TC

    This instrument cuts up to 1.5 mm wire with ease due to its triple action design. Minimum Cutting Capacity: 0.36 mm Maximum Cutting Capacity: Wire up to 1.5 mm.

http://www.eksenmedikal.com.tr/e-529-heavy-duty-cutter-tc

G4™ Nickel Titanium - Bioform III - G4orce™

G4™ Nickel Titanium - Bioform III - G4orce™

Bioform III MBT* Tapered / Ideal** CompatibleG4orce™ is a G4™ Nickel Titanium wire with 3 distinct zones offering progressive forces that increase from anterior to posterior. Light anterior force (100g), medium cuspid/bicuspid force (200g), and a heavy molar force (300g) when applied to a 19x25 wire.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-bioform-iii-g4orce

G4™ Nickel Titanium - Trueform™ I - G4orce™

G4™ Nickel Titanium - Trueform™ I - G4orce™

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleG4orce™ is a G4™ Nickel Titanium wire with 3 distinct zones offering progressive forces that increase from anterior to posterior. Light anterior force (100g), medium cuspid/bicuspid force (200g), and a heavy molar force (300g) when applied to a 19x25 wire.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-trueform-i-g4orce

Alpha-Dent® Alginate Impression Material

Alpha-Dent® Alginate Impression Material

Alpha-Dent® Alginate Impression Material is available in a variety of flavors and set types. This heavy body material is designed to produce consistent impressions. Each can includes powder scoop and vial.

http://www.eksenmedikal.com.tr/alpha-dent-alginate-impression-material

G&amp;H G4™ Nickel Titanium Open Coil Springs

G&H G4™ Nickel Titanium Open Coil Springs

Open coil springs open and maintain space gently and efficiently in a convenient cut to length design.Choose from (3) 7" straight lengths or (1) 21" SpoolPrecision formed G4™ Nickel Titanium alloy into closed coil springs. G4™ Nickel Titaniam springs provide consistent force and remain active until the space is closed. Consistent force values and full recovery are both routinely achieved with G4™ Nickel Titanium. *Forces determined by compressing a 1" open coil spring. Wire Size I.D. Force Compressed 25% (.250") Compressed 50% (.500") .009" .030 Extra Light 95 g 225 g .010" .030 Light 120 g 260 g .010" .036 Medium Light 90 g 200 g .012" .030 Medium 220 g 480 g .012" .036 Medium Heavy 180 g 380 g .014" .030 Heavy 360 g 700 g .014" .036 Extra Heavy 270 g 560 g .010" .045 Facebow 50 g 120 g

http://www.eksenmedikal.com.tr/g-h-g4-nickel-titanium-open-coil-springs

GAC Open Coil Spring

GAC Open Coil Spring

Open, or compression, coils are 15mm in length when passive and may be compressed to 3mm. Between these points, the coil will exert 50 (extra light), 100 (light), 150 (medium), 200 (heavy), or 250 (extra heavy) , and 300 (XX Heavy) grams of force until 14mm, and then the force falls to 0 as it becomes passive again. No distortion will occur during movement. These low forces limit patient discomfort and ensure good circulation in the periodontal pocket during movement. Typically, you will see 4mm of space opened in three months (this varies depending on the age and health of the patient). To engage the open coils, mark the archwire where the mesial and distal tooth destinations are located. Crimp on the mesial stop and ligate the archwire up to the point where the spring is to be placed. Slide the coil over the archwire and crimp on the distal stops. Ligate the balance of the wire. Since the Sentalloy coil needs about 1/10 as much wire as steel, good hygiene is much easier, but do advise the patient to rinse and brush around the coil. No other adjustment is needed.

http://www.eksenmedikal.com.tr/open-coil-spring

 
3WTURK CMS v6.03WTURK CMS v6.0