Arama Sonuçları..

Toplam 7 kayıt bulundu.
<b class=red>Sentalloy</b> Round

Sentalloy Round

  Used as an initial archwire, the superelastic NiTi wire provides near constant forces during the leveling and aligning stage of treatment. The Sentalloy wire family is designed to deliver a gentle, light continuous force to mitigate periodontal stress. UNIQUE PROPERTIES OF SENTALLOY SUPERELASTIC WIRES Body Heat Activation At room temperature, Sentalloy wires are soft, pliable, and easy to engage. Once warmed to body temperature the wire gently and predictably guides the teeth to the present arch form. Superelasticity Even when severely malposed, Sentalloy continues to exert its gentle, near constant forces as the tooth moves. Shape Memory Effect Sentalloy will take displacements up to 90 degrees without deforming. Its overwhelming desire to return to its original shape actually promotes tooth movement with fewer 0wire changes and fewer patient visits.

http://www.eksenmedikal.com.tr/sentalloy-round

Lingual Archwires

Lingual Archwires

DENTPSLY GAC’s lingual archwires are available in Sentalloy, NeoSentalloy and Beta Titanium. These are wires that are recommended to be used with our lingual bracket lines, InOvation L and MTM No•Trace™. Wires are available in .012”, .014”, .016”, .017" x .025" and .016" x .022".

http://www.eksenmedikal.com.tr/lingual-archwires

Neo<b class=red>Sentalloy</b> - Square or Rectangluar

NeoSentalloy - Square or Rectangluar

Intermediate archwire with body heat activation and true superelasticity with near constant forces. Also available with IONGUARD. Neo-Sentalloy is part of the Sentalloy wire family sharing the same properties designed to deliver a gentle, light continuous force to mitigate periodontal stress. UNIQUE PROPERTIES OF SENTALLOY SUPERELASTIC WIRES Body Heat Activation - At room temperature, Sentalloy wires are soft, pliable, and easy to engage. Once warmed to body temperature the wire gently and predictably guides the teeth to the present arch form. Superelasticity - Even when severely malposed, Sentalloy continues to exert its gentle, near constant forces as the tooth moves. Shape Memory Effect - Sentalloy will take displacements up to 90 degrees without deforming. Its overwhelming desire to return to its original shape actually promotes tooth movement with fewer 0wire changes and fewer patient visits. IONGUARD - IONGUARD is not a coating; it is a fundamental change in the wire’s surface. Without changing the wire’s dimensions, or altering any of the wire’s unique superelastic properties, the process produces sliding mechanics comparable to stainless steel, while sealing the occlusal surface to reduce nickel leaching and breakage.  

http://www.eksenmedikal.com.tr/neosentalloy-square-or-rectangluar

BioForce

BioForce

BioForce - Square or Rectangluar   Optimally biological forces begin at approximately 80 grams of force at the anteriors, and gradually increase to approximately 300 grams of force in the molars. Also available with IONGUARD. Optimal Tooth Movement and Ideal Biological Forces As this chart shows, the optimal force needed to move anteriors is not the same as the optimal force needed to move molars. If a force is designed to move anteriors, it is too light to move molars. If a force is great enough to move molars, the force is too strong - traumatically strong - for anteriors. Other wires offer one force at a time, requiring at least two or three wire changes to achieve the desired movement. BioForce exhibits low forces at the anterior, gradually increases force in the bicuspids, and again in the molars. Each tooth receives the optimal biological force necessary to move specific teeth in one wire. Anterior Region of arch form has the lowest heat-activated force, as anterior teeth have the lightest roots. The Bicuspid Region of the arch maintains a slightly greater heat-activated force to move larger rooted bicuspids. The Posterior Region of the arch form has the greatest heat-activated force within the archwire for moving thestrong-rooted molars. BioForce also shares the properties of all Sentalloy wires and is designed to deliver a gentle, light continuous force to mitigate periodontal stress. UNIQUE PROPERTIES OF SENTALLOY SUPERELASTIC WIRES Body Heat Activation At room temperature, Sentalloy wires are soft, pliable, and easy to engage. Once warmed to body temperature the wire gently and predictably guides the teeth to the present arch form. Superelasticity Even when severely malposed, Sentalloy continues to exert its gentle, near constant forces as the tooth moves. Shape Memory Effect Sentalloy will take displacements up to 90 degrees without deforming. Its overwhelming desire to return to its original shape actually promotes tooth movement with fewer 0wire changes and fewer patient visits. IONGUARD - IONGUARD is not a coating; it is a fundamental change in the wire’s surface. Without changing the wire’s dimensions, or altering any of the wire’s unique superelastic properties, the process produces sliding mechanics comparable to stainless steel, while sealing the occlusal surface to reduce nickel leaching and breakage.

http://www.eksenmedikal.com.tr/bioforce-square-or-rectangluar

GAC Stop Wound Open Coil Spring

GAC Stop Wound Open Coil Spring

Sentalloy Stop Wound Open Coil Springs are packaged individually or in three 7” lengths to a tube. Each length is quadruple wound every 4mm. After determining the length of coil needed, simply cut the wire at the center of the tight spiral as indicated below: The quadruple wind can be cut by having one person stretch the wind while another person makes the cut; or by using a separating plier to stretch the wind and a hard wire cutter to make the cut. Sentalloy Stop Wound Open Coils with a standard lumen of .035” are available in forces of 50, 100, 150 and 200 grams. (.045” compatible coils are available in 150 grams of force only.)

http://www.eksenmedikal.com.tr/stop-wound-open-coil-spring

GAC Open Coil Spring

GAC Open Coil Spring

Open, or compression, coils are 15mm in length when passive and may be compressed to 3mm. Between these points, the coil will exert 50 (extra light), 100 (light), 150 (medium), 200 (heavy), or 250 (extra heavy) , and 300 (XX Heavy) grams of force until 14mm, and then the force falls to 0 as it becomes passive again. No distortion will occur during movement. These low forces limit patient discomfort and ensure good circulation in the periodontal pocket during movement. Typically, you will see 4mm of space opened in three months (this varies depending on the age and health of the patient). To engage the open coils, mark the archwire where the mesial and distal tooth destinations are located. Crimp on the mesial stop and ligate the archwire up to the point where the spring is to be placed. Slide the coil over the archwire and crimp on the distal stops. Ligate the balance of the wire. Since the Sentalloy coil needs about 1/10 as much wire as steel, good hygiene is much easier, but do advise the patient to rinse and brush around the coil. No other adjustment is needed.

http://www.eksenmedikal.com.tr/open-coil-spring

GAC <b class=red>Sentalloy</b>® Closed Coil Springs

GAC Sentalloy® Closed Coil Springs

Closing spaces with closed Sentalloy coil springs brings exceptional results.   TWO DESIGNS ARE AVAILABLE: Two Eyelet Design: The initial length is 3mm unactivated (this does not include the eyelet lengths). These can be activated to 15mm without any deformation or change in force. No change in force will be seen as the coil contracts, reducing the space. To engage, slide over a molar hook and slowly stretch to the post on the cuspid bracket or a sliding hook on the archwire. Use a locking Mathieu plier on the widened platform of the eyelet. If you do not use the cuspid post, tie the archwire to the tooth you wish to move, slide on the sliding hook, then tie in the balance of the wire. Now engage the spring as above. For an eyelet with ligature wire, you have the option of hooking the eyelet on the molar, then activating the spring and tying it to the cuspid bracket with the .008” ligature wire. Should you wish to span an area greater than 15mm, measure the span first. Then place the coil on the molar hook and activate the coil 10mm. Tie the ligature wire to the bracket. 

http://www.eksenmedikal.com.tr/gac-sentalloy-closed-coil-springs

 
3WTURK CMS v6.03WTURK CMS v6.0