<b class=red>M5™</b> Copper Niti - Europa™ Form II - Platinum Proportion®

M5™ Copper Niti - Europa™ Form II - Platinum Proportion®

Europa™ Form II @ 92% & 84% Damon* CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystallized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.

http://www.eksenmedikal.com.tr/m5-copper-niti-europa-form-ii-platinum-proportion

<b class=red>M5™</b> Copper Nickel Titanium - Bioform I

M5™ Copper Nickel Titanium - Bioform I

Bioform I A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-bioform-i

<b class=red>M5™</b> Copper Nickel Titanium - Bioform II

M5™ Copper Nickel Titanium - Bioform II

Bioform II A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-bioform-ii

<b class=red>M5™</b> Copper Nickel Titanium - Bioform III

M5™ Copper Nickel Titanium - Bioform III

Bioform III MBT* Tapered / Ideal** CompatibleA premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-bioform-iii

<b class=red>M5™</b> Copper Nickel Titanium - Bioform IV

M5™ Copper Nickel Titanium - Bioform IV

Bioform IV A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-bioform-iv

<b class=red>M5™</b> Copper Nickel Titanium - Bioform V

M5™ Copper Nickel Titanium - Bioform V

  Bioform V A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-bioform-v

<b class=red>M5™</b> Copper Nickel Titanium - Europa™ Form I

M5™ Copper Nickel Titanium - Europa™ Form I

Europa™ Form I MBT* Ovoid CompatibleA premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-europa-form-i

<b class=red>M5™</b> Copper Nickel Titanium - Europa™ Form II

M5™ Copper Nickel Titanium - Europa™ Form II

  Europa™ Form II Damon* CompatibleA premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-europa-form-ii

<b class=red>M5™</b> Copper Nickel Titanium - Preformed Lingual

M5™ Copper Nickel Titanium - Preformed Lingual

Preformed Lingual These archforms were developed to meet the challenging mechanics of modern lingual treatment - designed and adapted precisely to lingual anatomy. Three anterior sizes in both upper and lower ensure a proper fit.A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-preformed-lingual

<b class=red>M5™</b> Copper Nickel Titanium - Reverse Curve I

M5™ Copper Nickel Titanium - Reverse Curve I

Reverse Curve I Original with moderate curve, torque and distal toe-in.A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-reverse-curve-i

<b class=red>M5™</b> Copper Nickel Titanium - Reverse Curve III

M5™ Copper Nickel Titanium - Reverse Curve III

Reverse Curve III Straight Leg, identical to our Trueform™ I shape with moderate curve and no distal toe-in or posterior torque.A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-reverse-curve-iii

<b class=red>M5™</b> Copper Nickel Titanium - Standard Form

M5™ Copper Nickel Titanium - Standard Form

Standard Form A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-standard-form

<b class=red>M5™</b> Copper Nickel Titanium - Trueform™ I

M5™ Copper Nickel Titanium - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleA premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-trueform-i

<b class=red>M5™</b> Copper Nickel Titanium - Trueform™ II

M5™ Copper Nickel Titanium - Trueform™ II

Trueform™ II A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-trueform-ii

 