Arama Sonuçları..

Toplam 65 kayıt bulundu.

BT3™ Beta <b class=red>Titanium</b> - Europa™ Form II - Platinum Proportion®

BT3™ Beta Titanium - Europa™ Form II - Platinum Proportion®

Europa™ Form II @ 92% & 84% Damon* CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.Pack of 25Pack of 10 (Solo-Pack™ option)*G&H is in no way affiliated with or endorsed by Ormco Corp. or Dr. Dwight DamonPlatinum Proportion is a registered service mark owned by Dr. Robert L. Waugh

http://www.eksenmedikal.com.tr/bt3-beta-titanium-europa-form-ii-platinum-proportion

M5™ Copper Nickel <b class=red>Titanium</b> - Bioform I

M5™ Copper Nickel Titanium - Bioform I

Bioform I A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-bioform-i

G4™ Nickel <b class=red>Titanium</b> - Europa™ Form II - Platinum Proportion®

G4™ Nickel Titanium - Europa™ Form II - Platinum Proportion®

Europa™ Form II @ 92% & 84% Damon* CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-europa-form-ii-platinum-proportion

G4™ Nickel <b class=red>Titanium</b> - Tooth Colored - Bioform III

G4™ Nickel Titanium - Tooth Colored - Bioform III

Bioform III MBT* Tapered / Ideal** CompatibleTooth-Colored, epoxy coated archwires necessitate the use of base wires that are .002" smaller than the final coated dimensions, so please consider this when selecting wires to ensure performance will be compatible with treatment objectives.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-tooth-colored-bioform-iii

G4™ Nickel <b class=red>Titanium</b> - Bioform I

G4™ Nickel Titanium - Bioform I

  Bioform I G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-bioform-i

Lingual Archwires

Lingual Archwires

DENTPSLY GAC’s lingual archwires are available in Sentalloy, NeoSentalloy and Beta Titanium. These are wires that are recommended to be used with our lingual bracket lines, InOvation L and MTM No•Trace™. Wires are available in .012”, .014”, .016”, .017" x .025" and .016" x .022".

http://www.eksenmedikal.com.tr/lingual-archwires

BT3™ Beta <b class=red>Titanium</b> - Trueform™ I - Platinum Proportion®

BT3™ Beta Titanium - Trueform™ I - Platinum Proportion®

Trueform™ I @ 92% & 84% Roth / MBT* Square / Tru-Arch** CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.Pack of 25Pack of 10 (Solo-Pack™ option)*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of OrmcoPlatinum Proportion is a registered service mark owned by Dr. Robert L. Waugh

http://www.eksenmedikal.com.tr/bt3-beta-titanium-trueform-i-platinum-proportion

M5™ Copper Nickel <b class=red>Titanium</b> - Bioform II

M5™ Copper Nickel Titanium - Bioform II

Bioform II A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-bioform-ii

G4™ Nickel <b class=red>Titanium</b> - Trueform™ I - Platinum Proportion®

G4™ Nickel Titanium - Trueform™ I - Platinum Proportion®

  Trueform™ I @ 92% & 84% Roth / MBT* Square / Tru-Arch** CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-trueform-i-platinum-proportion

G4™ Nickel <b class=red>Titanium</b> - Trueform™ I - Platinum Proportion®

G4™ Nickel Titanium - Trueform™ I - Platinum Proportion®

  Trueform™ I @ 92% & 84% Roth / MBT* Square / Tru-Arch** CompatibleThese archforms are designed for treatment of patients with smaller tooth anatomy and/or spacing. After measuring all anterior teeth for over five years, Dr. Robert L. Waugh has crystalized a method to consistently deliver a predictable anterior display while idealizing functional coupling of anterior teeth.The Platinum Proportion® Archwire System takes the guess work out of archwire selection based on a simple system of measuring tooth width of the anteriors - cuspid to cuspid. This technique definitively provides the clinician the proper archwire based on the consolidated width.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-trueform-i-platinum-proportion-1

G4™ Nickel <b class=red>Titanium</b> - Tooth Colored - Europa™ Form I

G4™ Nickel Titanium - Tooth Colored - Europa™ Form I

Europa™ Form I MBT* Ovoid CompatibleTooth-Colored, epoxy coated archwires necessitate the use of base wires that are .002" smaller than the final coated dimensions, so please consider this when selecting wires to ensure performance will be compatible with treatment objectives.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-tooth-colored-europa-form-i

G4™ Nickel <b class=red>Titanium</b> - Bioform II

G4™ Nickel Titanium - Bioform II

  Bioform II G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-bioform-ii

M5™ Copper Nickel <b class=red>Titanium</b> - Bioform III

M5™ Copper Nickel Titanium - Bioform III

Bioform III MBT* Tapered / Ideal** CompatibleA premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-bioform-iii

G4™ Nickel <b class=red>Titanium</b> - Tooth Colored - Europa™ Form II

G4™ Nickel Titanium - Tooth Colored - Europa™ Form II

Europa™ Form II Damon* CompatibleTooth-Colored, epoxy coated archwires necessitate the use of base wires that are .002" smaller than the final coated dimensions, so please consider this when selecting wires to ensure performance will be compatible with treatment objectives.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-tooth-colored-europa-form-ii

G4™ Nickel <b class=red>Titanium</b> - Bioform III

G4™ Nickel Titanium - Bioform III

Bioform III MBT* Tapered / Ideal** CompatibleG4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-bioform-iii

M5™ Copper Nickel <b class=red>Titanium</b> - Bioform IV

M5™ Copper Nickel Titanium - Bioform IV

Bioform IV A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-bioform-iv

G4™ Nickel <b class=red>Titanium</b> - Tooth Colored - Reverse Curve I

G4™ Nickel Titanium - Tooth Colored - Reverse Curve I

Reverse Curve I Original with moderate curve, torque and distal toe-in.Tooth-Colored, epoxy coated archwires necessitate the use of base wires that are .002" smaller than the final coated dimensions, so please consider this when selecting wires to ensure performance will be compatible with treatment objectives.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-tooth-colored-reverse-curve-i

G4™ Nickel <b class=red>Titanium</b> - Bioform III - G4orce™

G4™ Nickel Titanium - Bioform III - G4orce™

Bioform III MBT* Tapered / Ideal** CompatibleG4orce™ is a G4™ Nickel Titanium wire with 3 distinct zones offering progressive forces that increase from anterior to posterior. Light anterior force (100g), medium cuspid/bicuspid force (200g), and a heavy molar force (300g) when applied to a 19x25 wire.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-bioform-iii-g4orce

Copperloy®

Copperloy®

Copperloy® Nickel Titanium - The Nimble Copper Wire   The Copperloy family is designed to deliver a comfortable and efficient experience. The addition of copper enhances the thermal properties of the wire.  UNIQUE PROPERTIES OF COPPERLOY SUPERELASTIC WIRES Scientifically Proven - Precision engineered Copper NiTi allows the wire to express fast, consistent movement. Consistent Performance - Achieve a steady, complete expression of force across all wire sizes for a more precise finishing point. Copper NiTi wires are also more resistant to permanent deformation. Resists Breakage - Controlled load ranges to reduce breakage. Easy Engagement -Due to low hysteresis, the smaller loading forces make wire engagement in the slot easier, even in severe cases. Available in a wide range of sizes, force levels and transformation temperatures. Midline etched and select sizes available with stops.

http://www.eksenmedikal.com.tr/copperloy-nickel-titanium-the-nimble-copper-wire

M5™ Copper Nickel <b class=red>Titanium</b> - Bioform V

M5™ Copper Nickel Titanium - Bioform V

  Bioform V A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-bioform-v

G4™ Nickel <b class=red>Titanium</b> - Tooth Colored - Trueform™ I

G4™ Nickel Titanium - Tooth Colored - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleTooth-Colored, epoxy coated archwires necessitate the use of base wires that are .002" smaller than the final coated dimensions, so please consider this when selecting wires to ensure performance will be compatible with treatment objectives.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-tooth-colored-trueform-i

G4™ Nickel <b class=red>Titanium</b> - Bioform IV

G4™ Nickel Titanium - Bioform IV

Bioform IV G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-bioform-iv

M5™ Copper Nickel <b class=red>Titanium</b> - Europa™ Form I

M5™ Copper Nickel Titanium - Europa™ Form I

Europa™ Form I MBT* Ovoid CompatibleA premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-europa-form-i

G4™ Nickel <b class=red>Titanium</b> - Bioform V

G4™ Nickel Titanium - Bioform V

Bioform V G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-bioform-v

M5™ Copper Nickel <b class=red>Titanium</b> - Europa™ Form II

M5™ Copper Nickel Titanium - Europa™ Form II

  Europa™ Form II Damon* CompatibleA premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-europa-form-ii

G4™ Nickel <b class=red>Titanium</b> - Europa™ Form I

G4™ Nickel Titanium - Europa™ Form I

Europa™ Form I MBT* Ovoid CompatibleG4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-europa-form-i

M5™ Copper Nickel <b class=red>Titanium</b> - Preformed Lingual

M5™ Copper Nickel Titanium - Preformed Lingual

Preformed Lingual These archforms were developed to meet the challenging mechanics of modern lingual treatment - designed and adapted precisely to lingual anatomy. Three anterior sizes in both upper and lower ensure a proper fit.A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-preformed-lingual

G4™ Nickel <b class=red>Titanium</b> - Europa™ Form II

G4™ Nickel Titanium - Europa™ Form II

Europa™ Form II Damon* CompatibleG4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-europa-form-ii

M5™ Copper Nickel <b class=red>Titanium</b> - Reverse Curve I

M5™ Copper Nickel Titanium - Reverse Curve I

Reverse Curve I Original with moderate curve, torque and distal toe-in.A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-reverse-curve-i

G4™ Nickel <b class=red>Titanium</b> - Reverse Curve - Europa™ Form II

G4™ Nickel Titanium - Reverse Curve - Europa™ Form II

Europa™ Form II Reverse Curve Damon* CompatibleReverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-reverse-curve-europa-form-ii

M5™ Copper Nickel <b class=red>Titanium</b> - Reverse Curve III

M5™ Copper Nickel Titanium - Reverse Curve III

Reverse Curve III Straight Leg, identical to our Trueform™ I shape with moderate curve and no distal toe-in or posterior torque.A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-reverse-curve-iii

G4™ Nickel <b class=red>Titanium</b> - Pre Torqued - Europa™ Form II

G4™ Nickel Titanium - Pre Torqued - Europa™ Form II

Europa™ Form II Damon* CompatibleEffective on both upper and lower arches, our 20° pre-torqued nickel titanium wires provide early and continuous translation of torque forces to anteriors that can be applied labially or lingually, simply by reversing the orientation of the wire.Available in 3 mm span sizes. Typically, a 28mm span is applied to the lower arch, 34mm & 38mm for the upper. To select proper mm span, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-pre-torqued-europa-form-ii

M5™ Copper Nickel <b class=red>Titanium</b> - Standard Form

M5™ Copper Nickel Titanium - Standard Form

Standard Form A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-standard-form

G4™ Nickel <b class=red>Titanium</b> - Pre Torqued - RC - Europa™ Form II

G4™ Nickel Titanium - Pre Torqued - RC - Europa™ Form II

Europa™ Form II Reverse Curve Damon* CompatibleEffective on both upper and lower arches, our 20° pre-torqued nickel titanium wires provide early and continuous translation of torque forces to anteriors that can be applied labially or lingually, simply by reversing the orientation of the wire.Available in 3 mm span sizes. Typically, a 28mm span is applied to the lower arch, 34mm & 38mm for the upper. To select proper mm span, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-pre-torqued-rc-europa-form-ii

M5™ Copper Nickel <b class=red>Titanium</b> - Trueform™ I

M5™ Copper Nickel Titanium - Trueform™ I

Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleA premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-trueform-i

G4™ Nickel <b class=red>Titanium</b> - Preformed Lingual

G4™ Nickel Titanium - Preformed Lingual

Preformed Lingual These archforms were developed to meet the challenging mechanics of modern lingual treatment - designed and adapted precisely to lingual anatomy. Three anterior sizes in both upper and lower ensure a proper fit.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-preformed-lingual


M5™ Copper Nickel <b class=red>Titanium</b> - Trueform™ II

M5™ Copper Nickel Titanium - Trueform™ II

Trueform™ II A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.

http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-trueform-ii

G4™ Nickel <b class=red>Titanium</b> - Universal Lingual

G4™ Nickel Titanium - Universal Lingual

Universal Lingual These universal archforms allow the clinician to apply the offset bends to adapt precisely to lingual anatomy.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-universal-lingual

G4™ Nickel <b class=red>Titanium</b> - Reverse Curve I

G4™ Nickel Titanium - Reverse Curve I

Reverse Curve I Original with moderate curve, torque and distal toe-in.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-reverse-curve-i

BT3™ Beta <b class=red>Titanium</b> - Bioform III

BT3™ Beta Titanium - Bioform III

Bioform III MBT* Tapered / Ideal** CompatibleOur Nickel-Free BT3™ Beta Titanium provides force levels that are 45% less than those of equivalent stainless steel arches and represents the latest material science available in Titanium Molybdenum archwires.The moderate force alternative to Stainless Steel archwires.Pack of 10Pack of 10 (Solo-Pack™ option)*MBT is trademark of 3M Unitek **Ideal is a trademark of Dentsply GAC Intl.

http://www.eksenmedikal.com.tr/bt3-beta-titanium-bioform-iii

G4™ Nickel <b class=red>Titanium</b> - Pre Torqued - Reverse Curve I

G4™ Nickel Titanium - Pre Torqued - Reverse Curve I

Reverse Curve I Original with moderate curve, torque and distal toe-in.Effective on both upper and lower arches, our 20° pre-torqued nickel titanium wires provide early and continuous translation of torque forces to anteriors that can be applied labially or lingually, simply by reversing the orientation of the wire.Available in 3 mm span sizes. Typically, a 28mm span is applied to the lower arch, 34mm & 38mm for the upper. To select proper mm span, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-pre-torqued-reverse-curve-i


BT3™ Beta <b class=red>Titanium</b> - Europa™ Form I

BT3™ Beta Titanium - Europa™ Form I

Europa™ Form I MBT* Ovoid CompatibleOur Nickel-Free BT3™ Beta Titanium provides force levels that are 45% less than those of equivalent stainless steel arches and represents the latest material science available in Titanium Molybdenum archwires.The moderate force alternative to Stainless Steel archwires.Pack of 10Pack of 10 (Solo-Pack™ option)*MBT is trademark of 3M Unitek

http://www.eksenmedikal.com.tr/bt3-beta-titanium-europa-form-i

G4™ Nickel <b class=red>Titanium</b> - Reverse Curve III

G4™ Nickel Titanium - Reverse Curve III

Reverse Curve III Straight Leg, identical to our Trueform™ I shape with moderate curve and no distal toe-in or posterior torque.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-reverse-curve-iii


BT3™ Beta <b class=red>Titanium</b> - Europa™ Form II

BT3™ Beta Titanium - Europa™ Form II

Europa™ Form II Damon* CompatibleOur Nickel-Free BT3™ Beta Titanium provides force levels that are 45% less than those of equivalent stainless steel arches and represents the latest material science available in Titanium Molybdenum archwires.The moderate force alternative to Stainless Steel archwires.Pack of 10Pack of 10 (Solo-Pack™ option)*G&H is in no way affiliated with or endorsed by Ormco Corp. or Dr. Dwight Damon

http://www.eksenmedikal.com.tr/bt3-beta-titanium-europa-form-ii

G4™ Nickel <b class=red>Titanium</b> - Standard Form

G4™ Nickel Titanium - Standard Form

Standard Form G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.

http://www.eksenmedikal.com.tr/g4-nickel-titanium-standard-form

BT3™ Beta <b class=red>Titanium</b> Lingual - Universal

BT3™ Beta Titanium Lingual - Universal

Universal Lingual Archwire developed from BT3™ Beta Titanium. These universal archforms allow the clinician to apply the offset bends to adapt precisely to lingual anatomy.Also available in Stainless SteelPack of 5Pack of 5 (Solo-Pack™ option)

http://www.eksenmedikal.com.tr/bt3-beta-titanium-lingual-universal

 
3WTURK CMS v6.03WTURK CMS v6.0