Arama Sonuçları..
Toplam 33 kayıt bulundu.
678-113 Slim Flush Cut Distal End Cutter
SLIM FLUSH CUT AND HOLD DISTAL END CUTTER
http://www.eksenmedikal.com.tr/678-113678-506 Distal Cinch Back İnstrument
DISTAL CINCH BACK HAND INSTRUMENT Bends archwire distal to the 1st or 2nd molar; maxium wire size .021"x.025" (.53 mm x 64 mm).
http://www.eksenmedikal.com.tr/678-506Stainless Steel - Ball Post - Bioform III
Bioform III MBT* Tapered / Ideal** CompatibleOur exclusive XR1™ Ball Post archwires offer the comfort and retention of ball ends plus a bendable brass post.A G&H proprietary soldering technique ensures clean, strong and consistent joints. The 16x22 or 19x25 XR1™ stainless base wire is heat treated and stress relieved – increasing the resiliency of the wire to improve mechanics.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Posted Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Ideal is a trademark of Dentsply GAC Intl.
http://www.eksenmedikal.com.tr/stainless-steel-ball-post-bioform-iiiStainless Steel - Keyhole 2 Loop - Trueform™ I
Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleLooped archwires offer excellent versatility for a variety of applications including anterior intrusion, space closure, elastic engagement, anterior retraction, etc.Looped archwires are offered in a range of sizes to accommodate most patients upper and lower arches, locating the loops between the lateral and cuspid. Manipulate anterior and posterior segments by activating the loops independently or in unison.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Looped Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco
http://www.eksenmedikal.com.tr/stainless-steel-keyhole-2-loop-trueform-iOmniArch®
OmniArch is the first mid-sized bracket system that combines all the outstanding elements of the proven twin system with the most advanced bracket design available. Clinicians gain superior control, wedged torque in base, easy bonding; patients benefit from a bracket that is comfortable, aesthetically pleasing, and from outstanding results. Conveniently, OmniArch is available in a wide. OmniArch brings you all the benefits and advantages ofthe latest orthodontic technology. Its low profile and compactrhomboid shape is comfortable and attractive. Design Features Aligned angulation designed for optimal mesido-distal/inciso-gingival orientation Wedged torque for aligned slots and placement advantages Low profile provides greater comfort Mid-sized and rhomboid shaped for designed for improved performance and esthetics Smooth finish designed for less irritation Permanent ID facilitates bracket management Center scribe line assists with bracket placement Chamfered slot walls Approximately 30% smaller than traditional style brackets, MicroArch is attractive and subtle in appearance to help your patients feel more confident and self-assured while in treatment.
http://www.eksenmedikal.com.tr/omniarchNK-251NiTi Distal Cinch Back Plier
Cinch and bends NiTi wire distal to buccal tube. Wire up to .025" (.063 mm)
http://www.eksenmedikal.com.tr/nk-251niti-distal-cinch-back-plier678-101 Distal End Cutter
UNIVERSAL CUT AND HOLD DISTAL END CUTTER
http://www.eksenmedikal.com.tr/678-101Stainless Steel - Ball Post - Europa™ Form I
Europa™ Form I MBT* Ovoid CompatibleOur exclusive XR1™ Ball Post archwires offer the comfort and retention of ball ends plus a bendable brass post.A G&H proprietary soldering technique ensures clean, strong and consistent joints. The 17x25 or 19x25 XR1™ stainless base wire is heat treated and stress relieved – increasing the resiliency of the wire to improve mechanics.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Posted Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is trademark of 3M Unitek
http://www.eksenmedikal.com.tr/stainless-steel-ball-post-europa-form-iStainless Steel - Keyhole 4 Loop - Trueform™ I
Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleLooped archwires offer excellent versatility for a variety of applications including anterior intrusion, space closure, elastic engagement, anterior retraction, etc.Looped archwires are offered in a range of sizes to accommodate most patients upper and lower arches, locating the loops between the lateral and cuspid. Manipulate anterior and posterior segments by activating the loops independently or in unison.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Looped Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco
http://www.eksenmedikal.com.tr/stainless-steel-keyhole-4-loop-trueform-iNEOSmile™ Tooth Positioner
The NEOsmile™ is a preformed tooth positioner that will idealize the patient's finishing occlusion upon debanding. The NEOsmile™ will maintain a Class I ideal relationship and provide some buffering against TMJ related irritations. Each NEOsmile™ incorporates molded airholes for unencumbered breathing. Like a custom tooth positioner, the NEOsmile™ is seated on the upper arch posterior on one side and stretched to the opposite side. Then the patient can gently clench to fully occlude into the appliance.TYPICAL INDICATED APPLICATIONSModerate space closure, band spaces, minor to moderate diastema closure, 3-4° torque, 5-8° rotation, and minor to moderate uprighting can be achieved where space is available.Generalized spacing may be corrected by staging sizes of the NEOsmile™. When generalized spacing is present and NEOsmile™ is fitted to the patient, it is typically recommended to use a size smaller than the patient's measured size. Patients with moderate generalized spacing may require the use of two concurrent NEOsmile™ positioners in incrementally smaller sizes to achieve ideal results.SELECTING THE PROPER SIZEDetermine the patient size for the NEOsmile™ by measuring the millimeter span from distal of upper cuspid to distal of opposite cuspid along the incisal edges.Sold individuallyKit of 10 (includes 1 of 10 select sizes)
http://www.eksenmedikal.com.tr/neosmile-tooth-positionerIn-Ovation C - Esthetics without Compromise
The In-Ovation C self-ligating bracket is made from ceramic material that compares to the strength and performance of metal. A highly esthetic self-ligating bracket made from a special ceramic material with a rhodium processed clip for enhanced esthetics. The natural color of In-Ovation C makes the bracket a perfect fit for patients concerned about esthetics, while delivering functionality comparable to metal brackets. THE POWER OF INTERACTIVE™ CONTROL FROM START TO FINISH In-Ovation C provides you with the ability to start and effectively finish your treatment in one, simple system. Using the technique of your choice, In-Ovation C enables you to maintain the precise degree of control that you need for each phase of your patient’s treatment. In-Ovation C’s revolutionary Interactive™ technology means you can choose the degree of engagement between the bracket and wire. In-Ovation C can be passive for leveling and aligning, expressive where control is realized and free-sliding is maintained, or active for controlled, optimal finishing. The choice is yours – a benefit not found in “passive only” brackets. INTERACTIVE CONTROL Passive Phase – Small, round wires slide freely, initiating the tooth movement process as the archwire gently levels the teeth and coaxes them into alignment. Expressive Phase – Square or rectangular wires are gently seated into the base of the slot without contacting the clip. Programming is expressed, rotations are corrected and space closures are completed. Active Phase – Rectangular archwires extend beyond the slot to fully engage the clip, providing the active control necessary for functional finishing, uprighting of the roots and adjusting the torque. Practice Advantages In-Ovation C provides a great way to optimize your practice and expand treatment options. Studies consistently show that self-ligating brackets significantly lower frictional forces; offer faster, easier archwire changes; increase appointment intervals; and shorten patient treatment time. In-Ovation C is easy for doctors and staff to use. Designed for reliable performance, the bracket’s 100% mechanical lock base ensures reliable bonding, debonding and the ability to rebond. A specially designed interactive, Coballoy spring clip provides excellent Patient Advantages Superb esthetics provide the confidence your patients will love Less chairtime during visits Longer intervals between appointments Excellent results Improved oral hygiene The Art of Orthodontic Excellence Transluscent Ceramic Construction In-Ovation C brackets are manufactured from a high-tech ceramic that combines excellent translucency with strength and performance similar to that of steel. Reliable Mechanical Bonding In-Ovation C employs a proprietary process to form strong, undercut bonding nubs on the bottom of the bracket base. These provide excellent anchoring points for the adhesive, resulting in a bond that is 100% mechanical and debonds easily after treatment. Straight Wire Technology A true straight wire appliance is one in which all the brackets have been designed to guide teeth into their desired positions with a preformed wire. In-Ovation is a true straight wire appliance that features: Compound Contour Base Torque in the Base Programmed In-Out Control Level Slot Alignment True Twin Design Occlusal and gingival twin tie wings offer an optimal mesial, distal span for achieving superior rotation control. The elimination of the elastomeric ligatures increases your inter-bracket distance. Spring Clip The self-ligating clip extends fully through a vertical channel in the bracket body, enhancing the structural integrity of the clip. A unique rhodium treatment process provides a low-sheen surface for reduced visibility and enhanced aesthetics. Easy Opening and Closing The clip opens easily when pressure is applied occlusally to the gingival sphere using the Engage-C. This is the primary method for opening and closing the clip is the gingival sphere. If unable to access the gingival sphere you can also utilize the Opin notch on the facial surface of the clip applying gentle pressure occulsally with amini scaler. The clip can be closed with aninstrument or simple finger pressure on the incisal curve. Triple Chamfered Slot Walls Slot walls are beveled outward, facilitating wire engagement and reducing the chance of the archwire binding or crimping. Disto–Gingival Dimple A color-code on the disto-gingival tie wing provides immediate identification of the tooth for which the bracket is intended. A matching colored removable site gauge is also in the slot for position orientation. Smooth Swept Tie Wings Smooth, swept tie wings help to reduce occlusal interference while increasing patient comfort. Adequate undercuts allow easy anchoring for elastic chains or the fastening of color ties at the patient’s request.
http://www.eksenmedikal.com.tr/in-ovation-c-esthetics-without-compromiseStainless Steel - Ball Post - Europa™ Form II
Europa™ Form II Damon* CompatibleOur exclusive XR1™ Ball Post archwires offer the comfort and retention of ball ends plus a bendable brass post.A G&H proprietary soldering technique ensures clean, strong and consistent joints. The 16x25 or 19x25 XR1™ stainless base wire is heat treated and stress relieved – increasing the resiliency of the wire to improve mechanics.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Posted Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*G&H is in no way affiliated with or endorsed by Ormco Corp. or Dr. Dwight Damon
http://www.eksenmedikal.com.tr/stainless-steel-ball-post-europa-form-iiStainless Steel - T-Loop - Trueform™ I
Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleLooped archwires offer excellent versatility for a variety of applications including anterior intrusion, space closure, elastic engagement, anterior retraction, etc.Looped archwires are offered in a range of sizes to accommodate most patients upper and lower arches, locating the loops between the lateral and cuspid. Manipulate anterior and posterior segments by activating the loops independently or in unison.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Looped Archwire Kit of 100 wires size distribution MM Sizing 24 26 28 30 32 34 36 38 40 42 44 46 Quantity 5 10 10 10 5 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco
http://www.eksenmedikal.com.tr/stainless-steel-t-loop-trueform-iStainless Steel - Ball Post - Trueform™ I
Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleOur exclusive XR1™ Ball Post archwires offer the comfort and retention of ball ends plus a bendable brass post.A G&H proprietary soldering technique ensures clean, strong and consistent joints. The 16x22 or 19x25 XR1™ stainless base wire is heat treated and stress relieved – increasing the resiliency of the wire to improve mechanics.To select proper size looped arch, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler. Posted Archwire Kit of 100 wires size distribution MM Sizing 22 24 26 28 30 32 34 36 38 40 42 44 Quantity 5 5 10 10 10 5 10 10 10 10 10 5 Pack of 10*MBT is a trademark of 3M Unitek **Tru-Arch is a trademark of Ormco
http://www.eksenmedikal.com.tr/stainless-steel-ball-post-trueform-iG4™ Nickel Titanium - Tooth Colored - Reverse Curve I
Reverse Curve I Original with moderate curve, torque and distal toe-in.Tooth-Colored, epoxy coated archwires necessitate the use of base wires that are .002" smaller than the final coated dimensions, so please consider this when selecting wires to ensure performance will be compatible with treatment objectives.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.
http://www.eksenmedikal.com.tr/g4-nickel-titanium-tooth-colored-reverse-curve-iIn-Ovation® R - The Original
In-Ovation R has been recognized as an industry leader for over a decade. Thousands of clinicians worldwide have trusted In-Ovation to treat their patients. The precision and quality built into these brackets offers repeatable success, practice efficiencies and beautiful results every time. See how far In-Ovation R can take you, your patients and your practice. In-Ovation Means Interactive In-Ovation R provides you with the ability to start and effectively finish your treatment with one, simple system. Using the technique of your choice, In-Ovation R enables you to maintain the precise degree of control that you need for each phase of your patient’s treatment. In-Ovation R’s unique Interactive technology means you can choose the degree of engagement between the bracket and wire. It can be passive for leveling and aligning, expressive where control is realized and free-sliding is maintained, or active for controlled, optimal finishing. Passive Phase Expressive Phase Active Phase Small, round wires slide freely, initiating the tooth movement process as the archwire gently levels the teeth and coaxes them into alignment. Square or rectangular wires are gently seated into the base of the slot without contacting the clip. Programming is expressed, rotations are corrected and space closures are completed. Rectangular archwires extend beyond the slot to fully engage the clip, providing the active control necessary for functional finishing, uprighting of the roots and adjusting the torque. Practice Advantages Not all self-ligating brackets are created equal. In-Ovation R brackets were created to optimize the treatment process with precision engineering and true straight wire design. The In-Ovation orthodontic systems are the result of a keen understanding of human physiology and orthodontic engineering. The compound contoured base of the In-Ovation R bracket is designed to provide a precise anatomical fit across the enamel surface of the tooth. The smooth swept tie-wings are engineered to minimize occlusal interference in order to increase patient comfort. In addition, the chamfered archwire slot is designed to reduce chair time by facilitating wire engagement and reducing the chance of archwire binding or crimping. This dedication to quality and attention to detail is infused into every product that carries the In-Ovation name. Patient Advantages Today more than ever, patients are doing their part to better understand the options available to them. Savvy practices have come to recognize this as an opportunity, enabling you to offer the benefits of self-ligation as an adjunct to your talent, technique and reputation. In providing a self-ligating option, you’ll be able to offer your patients less chair time, fewer appointments and a cleaner, more esthetic appearance. In doing so, you’ll be able to create a perceived (and potentially significant) point of differentiation between your practice and the other competing practices in the area. In-Ovation R Dedication to Detail True Twin Design – Occlusal and gingival twin tie-wings offer an optimal mesial, distal span for achieving superior rotation control. The elimination of the elastomeric ligatures increase your inter-bracket distance. Spring Clip – The self-ligating clip extends fully through the vertical channel in the bracket body, enhancing the structural integrity of the clip. Base Design – The exclusive patented Palmer Notation laser etched into the mesh facilitates bracket management with a ready reference of the quadrant, tooth and prescription.An 80 gauge single mesh, compound contoured base provides a precise anatomical fit. Full Slot Slip Coverage – The In-Ovation R clip provides full coverage across the entire slot for superior rotational control. This allows the clip to interact with the wire both on the mesial and distal, as needed, without the need for auxiliaries. Straight Wire Technology In-Ovation is a completely adjusted true straight wire appliance system that positions teeth at all four dimensions: in/out, angulations, torque, and overcorrection. With this completely adjusted four dimensional appliance system you will need no offset bends in the archwires to obtain an optimal finish in most cases (if the brackets are optimally positioned on teeth). In order to be considered a completely four-dimensional appliance, the bracket must contain: Compound contour base Torque in base Proper in/out and anti-rotation Level slot alignment at the conclusion of appliance therapy Easy Open Clip – The clip opens easily when pressure is applied occlusally to the v-notched clip at the gingival side of the bracket, using the engage R or similar instrument. The clip can be closed with an instrument or simple finger pressure on the incisal curve. Triple Chamfered Slot Walls – Slot walls are beveled outward, facilitating wire engagement and reducing the chance of the archwire binding or crimping. Vertical Scribe Line – A scribe line on the bracket face aids positioning by providing a convenient reference for orienting the center line of the bracket with the facial axis of the clinical crown (FACC). Smooth Swept Tie-Wings –Help to reduce occlusal interference while increasing patient comfort. Adequate undercuts allow easy anchoring for elastic chains or the fastening of color ties at the patient’s request.
http://www.eksenmedikal.com.tr/in-ovation-r-the-originalNK-212 DİSTAL END CUTTER
It shear cuts hard and braided wire and then, holds the ends of the wire safely, so that it does not enter the soft tissue. The cutting edges are diamond honed.
http://www.eksenmedikal.com.tr/nk-212-distal-end-cutterM5™ Copper Nickel Titanium - Reverse Curve I
Reverse Curve I Original with moderate curve, torque and distal toe-in.A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.
http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-reverse-curve-iM5™ Copper Nickel Titanium - Reverse Curve III
Reverse Curve III Straight Leg, identical to our Trueform™ I shape with moderate curve and no distal toe-in or posterior torque.A premium nickel titanium wire that incorporates a precise temperature transformation at 27°C for predictable tooth moving forces. G&H quality manufacturing and testing processes make M5™ Copper Nickel Titanium distinct from all other archwires used in orthodontics.Many orthodontists induce the martensitic phase by chilling the wire below its transition temperature prior to placement. Following engagement, as the thermal wire elevates in temperature within the oral cavity, the transition from martensitic to austenitic phases causes the force level to increase and the shape memory phenomenon to occur.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.
http://www.eksenmedikal.com.tr/m5-copper-nickel-titanium-reverse-curve-iiiG4™ Nickel Titanium - Pre Torqued - Europa™ Form II
Europa™ Form II Damon* CompatibleEffective on both upper and lower arches, our 20° pre-torqued nickel titanium wires provide early and continuous translation of torque forces to anteriors that can be applied labially or lingually, simply by reversing the orientation of the wire.Available in 3 mm span sizes. Typically, a 28mm span is applied to the lower arch, 34mm & 38mm for the upper. To select proper mm span, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.
http://www.eksenmedikal.com.tr/g4-nickel-titanium-pre-torqued-europa-form-iiG4™ Nickel Titanium - Pre Torqued - RC - Europa™ Form II
Europa™ Form II Reverse Curve Damon* CompatibleEffective on both upper and lower arches, our 20° pre-torqued nickel titanium wires provide early and continuous translation of torque forces to anteriors that can be applied labially or lingually, simply by reversing the orientation of the wire.Available in 3 mm span sizes. Typically, a 28mm span is applied to the lower arch, 34mm & 38mm for the upper. To select proper mm span, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.
http://www.eksenmedikal.com.tr/g4-nickel-titanium-pre-torqued-rc-europa-form-iiG4™ Nickel Titanium - Reverse Curve I
Reverse Curve I Original with moderate curve, torque and distal toe-in.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.
http://www.eksenmedikal.com.tr/g4-nickel-titanium-reverse-curve-iG4™ Nickel Titanium - Pre Torqued - Reverse Curve I
Reverse Curve I Original with moderate curve, torque and distal toe-in.Effective on both upper and lower arches, our 20° pre-torqued nickel titanium wires provide early and continuous translation of torque forces to anteriors that can be applied labially or lingually, simply by reversing the orientation of the wire.Available in 3 mm span sizes. Typically, a 28mm span is applied to the lower arch, 34mm & 38mm for the upper. To select proper mm span, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.
http://www.eksenmedikal.com.tr/g4-nickel-titanium-pre-torqued-reverse-curve-iFacebows - Standard
Our high quality stainless steel .045 inner and .072 outer bows are laser welded together for maximum durability and comfort. Available in 5 inner bow sizes and 2 outer bow sizes. Medium outer bow is 12mm longer than the short outer bow.*Spans are measured from the distal of one bow loop to the distal of the other loop.Sold individually.
http://www.eksenmedikal.com.tr/facebows-standardG4™ Nickel Titanium - Reverse Curve III
Reverse Curve III Straight Leg, identical to our Trueform™ I shape with moderate curve and no distal toe-in or posterior torque.Reverse Curve archwires provide excellent counter forces to achieve bite modifications quickly and efficiently, while also improving archform integrity.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.
http://www.eksenmedikal.com.tr/g4-nickel-titanium-reverse-curve-iiiLip Bumpers
Lip Bumpers are precision shaped to relieve lip and cheek pressures and allow teeth to unravel quickly. Bumpers feature colored lip pad and include small ligating hooks for securing in place.Size 1 = 83mmSize 2 = 90mmSize 3 = 97mmSize 4 = 104mmSize 5 = 111mmAlso available in Universal*Spans are measured from the distal of one bow loop to the distal of the other loop.2 lip bumpers per package.
http://www.eksenmedikal.com.tr/lip-bumpersG4™ Nickel Titanium - Pre Torqued - Trueform™ I
Trueform™ I Roth / MBT* Square / Tru-Arch** CompatibleEffective on both upper and lower arches, our 20° pre-torqued nickel titanium wires provide early and continuous translation of torque forces to anteriors that can be applied labially or lingually, simply by reversing the orientation of the wire.Available in 3 mm span sizes. Typically, a 28mm span is applied to the lower arch, 34mm & 38mm for the upper. To select proper mm span, measure along incisal edge from distal of lateral to distal of opposite lateral with a mm ruler.G4™ Nickel Titanium is an uniquely enhanced alloy that has been exclusively formulated to yield consistent and specific force, memory, and elasticity values.The clinically significant characteristics of G4™ Nickel Titanium include lower initial load forces, for patient comfort, and increased residual forces as full shape recovery progresses. Teeth move farther and faster.
http://www.eksenmedikal.com.tr/g4-nickel-titanium-pre-torqued-trueform-iG&H 7" MOLAR DISTALIZING OPEN COIL SPRING .010x.045
Molar Distalizing Open Coil Springs deliver gentle 100 grams of force to achieve average 1mm to 1.5mm distalization per month without patient cooperation. Place over archwire and anchor with stop hook and elastics or Nance Appliance for maximum effectiveness. Intermittent closed coil sections allow for end stops when cut to length. .045" I.D.
http://www.eksenmedikal.com.tr/g-h-7-molar-distalizing-open-coil-spring-010x-045G&H SPRING, MOLAR DIST. 21" SPOOL
Molar Distalizing Open Coil Springs deliver gentle 100 grams of force to achieve average 1mm to 1.5mm distalization per month without patient cooperation. Place over archwire and anchor with stop hook and elastics or Nance Appliance for maximum effectiveness. Intermittent closed coil sections allow for end stops when cut to length. .045" I.D.
http://www.eksenmedikal.com.tr/g-h-spring-molar-dist-21-spoolG&H Palatal Arch Bars
Our palatal arch bars are formed in .036" stainless with double back bends for arch maintenance, molar rotation and distalization.Pack of 5Pack of 50 Kits5 of each for sizes 34 MM, 36 MM, 38 MM, 40 MM, 46 MM, & 52 MM. 10 of each for sizes 42 MM & 44 MM.
http://www.eksenmedikal.com.tr/g-h-palatal-arch-barsGAC Open Coil Spring
Open, or compression, coils are 15mm in length when passive and may be compressed to 3mm. Between these points, the coil will exert 50 (extra light), 100 (light), 150 (medium), 200 (heavy), or 250 (extra heavy) , and 300 (XX Heavy) grams of force until 14mm, and then the force falls to 0 as it becomes passive again. No distortion will occur during movement. These low forces limit patient discomfort and ensure good circulation in the periodontal pocket during movement. Typically, you will see 4mm of space opened in three months (this varies depending on the age and health of the patient). To engage the open coils, mark the archwire where the mesial and distal tooth destinations are located. Crimp on the mesial stop and ligate the archwire up to the point where the spring is to be placed. Slide the coil over the archwire and crimp on the distal stops. Ligate the balance of the wire. Since the Sentalloy coil needs about 1/10 as much wire as steel, good hygiene is much easier, but do advise the patient to rinse and brush around the coil. No other adjustment is needed.
http://www.eksenmedikal.com.tr/open-coil-springGAC Molar Distallization Coils
Maxillary molars can be moved distally in 4-7 months without patient cooperation using our 100 gram Stop Wound Open Coil Springs. A modified Nance or A.C.C.O. may be used as an anchorage device initially. The coils are placed between the 1st bicuspid and the 1st molar – by passing the 2nd bicuspid. The coils are then activated against the molar using an archwire lock or our special crimpable stop. Cut the Stop Wound Open Coils so that they extend to the end of the buccal tube. Ligate the archwire to the 1st bicuspid, set the stop, then slide the coil onto the archwire. Next, feed the archwire into the tube, ensuring that the archwire is fully inserted with 2mm of wire extending beyond the tube. Uprighting springs may be used from the 1st bicuspid to the distal of the laterals to control any anterior movement. Using this system, you will see 1mm per month in space gained, with any anchorage loss well within clinically acceptable limits.
http://www.eksenmedikal.com.tr/gac-molar-distallization-coils