Arama Sonuçları..
Toplam 22 kayıt bulundu.
OPAL Nickel Titanium Closed-Coil Springs
Nickel Titanium Closed-Coil Springs
http://www.eksenmedikal.com.tr/nickel-titanium-closed-coil-springs14" Straight Lengths
Our Stainless Steel Straight Lengths are manufactured from a 304v spring hard wire suitable for clinical and laboratory applications. Its superior resiliency resists deformation. 25 lengths per tube.
http://www.eksenmedikal.com.tr/14-straight-lengths-1In-Ovation C - Esthetics without Compromise
The In-Ovation C self-ligating bracket is made from ceramic material that compares to the strength and performance of metal. A highly esthetic self-ligating bracket made from a special ceramic material with a rhodium processed clip for enhanced esthetics. The natural color of In-Ovation C makes the bracket a perfect fit for patients concerned about esthetics, while delivering functionality comparable to metal brackets. THE POWER OF INTERACTIVE™ CONTROL FROM START TO FINISH In-Ovation C provides you with the ability to start and effectively finish your treatment in one, simple system. Using the technique of your choice, In-Ovation C enables you to maintain the precise degree of control that you need for each phase of your patient’s treatment. In-Ovation C’s revolutionary Interactive™ technology means you can choose the degree of engagement between the bracket and wire. In-Ovation C can be passive for leveling and aligning, expressive where control is realized and free-sliding is maintained, or active for controlled, optimal finishing. The choice is yours – a benefit not found in “passive only” brackets. INTERACTIVE CONTROL Passive Phase – Small, round wires slide freely, initiating the tooth movement process as the archwire gently levels the teeth and coaxes them into alignment. Expressive Phase – Square or rectangular wires are gently seated into the base of the slot without contacting the clip. Programming is expressed, rotations are corrected and space closures are completed. Active Phase – Rectangular archwires extend beyond the slot to fully engage the clip, providing the active control necessary for functional finishing, uprighting of the roots and adjusting the torque. Practice Advantages In-Ovation C provides a great way to optimize your practice and expand treatment options. Studies consistently show that self-ligating brackets significantly lower frictional forces; offer faster, easier archwire changes; increase appointment intervals; and shorten patient treatment time. In-Ovation C is easy for doctors and staff to use. Designed for reliable performance, the bracket’s 100% mechanical lock base ensures reliable bonding, debonding and the ability to rebond. A specially designed interactive, Coballoy spring clip provides excellent Patient Advantages Superb esthetics provide the confidence your patients will love Less chairtime during visits Longer intervals between appointments Excellent results Improved oral hygiene The Art of Orthodontic Excellence Transluscent Ceramic Construction In-Ovation C brackets are manufactured from a high-tech ceramic that combines excellent translucency with strength and performance similar to that of steel. Reliable Mechanical Bonding In-Ovation C employs a proprietary process to form strong, undercut bonding nubs on the bottom of the bracket base. These provide excellent anchoring points for the adhesive, resulting in a bond that is 100% mechanical and debonds easily after treatment. Straight Wire Technology A true straight wire appliance is one in which all the brackets have been designed to guide teeth into their desired positions with a preformed wire. In-Ovation is a true straight wire appliance that features: Compound Contour Base Torque in the Base Programmed In-Out Control Level Slot Alignment True Twin Design Occlusal and gingival twin tie wings offer an optimal mesial, distal span for achieving superior rotation control. The elimination of the elastomeric ligatures increases your inter-bracket distance. Spring Clip The self-ligating clip extends fully through a vertical channel in the bracket body, enhancing the structural integrity of the clip. A unique rhodium treatment process provides a low-sheen surface for reduced visibility and enhanced aesthetics. Easy Opening and Closing The clip opens easily when pressure is applied occlusally to the gingival sphere using the Engage-C. This is the primary method for opening and closing the clip is the gingival sphere. If unable to access the gingival sphere you can also utilize the Opin notch on the facial surface of the clip applying gentle pressure occulsally with amini scaler. The clip can be closed with aninstrument or simple finger pressure on the incisal curve. Triple Chamfered Slot Walls Slot walls are beveled outward, facilitating wire engagement and reducing the chance of the archwire binding or crimping. Disto–Gingival Dimple A color-code on the disto-gingival tie wing provides immediate identification of the tooth for which the bracket is intended. A matching colored removable site gauge is also in the slot for position orientation. Smooth Swept Tie Wings Smooth, swept tie wings help to reduce occlusal interference while increasing patient comfort. Adequate undercuts allow easy anchoring for elastic chains or the fastening of color ties at the patient’s request.
http://www.eksenmedikal.com.tr/in-ovation-c-esthetics-without-compromiseIn-Ovation® mini - Small Imprint, Big Impact
The In-Ovation® mini bracket is the smallest self-ligating twin bracket we’ve ever produced. Designed, developed and manufactured using the latest in micro-engineering technology, In-Ovation mini raises the bar on low-profile performance. From the innovative clip design to the patented Interactive™ technology that offers unmatched precision and control—In-Ovation® mini gives you the power to finish every case with the utmost precision. And with a smaller than other competitive interactive brackets your patients will love the esthetics and comfort level. Innovation means doing more with less, and no bracket does more for you, your practice, and your patients, than the In-Ovation mini. It’s the bracket you’ve always wanted, from the company you’ve always trusted. Programmed for Versatility In-Ovation® mini is proud to offer you the versatility of both interactive and passive design in a single unified system. It puts unprecedented treatment options in your hands. Passive cuspids and bicuspids are available in the posterior for lower friction sliding mechanics. INTERACTIVE CONTROL Passive Phase – Small, round wires slide freely, initiating the tooth movement process as the archwire gently levels the teeth and coaxes them into alignment. Expressive Phase – Square or rectangular wires are gently seated into the base of the slot without contacting the clip. Programming is expressed, rotations are corrected and space closures are completed. Active Phase – Rectangular archwires extend beyond the slot to fully engage the clip, providing the active control necessary for functional finishing, uprighting of the roots and adjusting the torque. Design Features Interactive Spring Clip Presents the utmost in control throughout treatment. True Twin Design Four tie-wings with adequate undercuts and integrated body channel allow easy anchoring of elastic chains or use of color ties at the patient’s request. Base Design An 80 gauge single mesh, compound contoured base provides a precise anatomical fit. Exclusive Patented Standard Palmer Notation laser etched into the mesh facilitates bracket management with a ready reference of the quadrant, tooth and prescription. Full Slot Clip Coverage For rotational control that limits the need for auxiliaries. Facial Scribe Line Added to the In-Ovation mini for simplified placement. True Straight Wire Design A true straight wire appliance is one in which all the brackets have been designed to guide the teeth into their ideal position with a preformed wire. In-Ovation® mini is a true straight wire appliance that features a compound contour base, torque in the base, programmed in-out control and level slot alignment. Easy Open Clip Affords a frustration-free procedure. Disto-Gingival Dimple A color code on the disto-gingival tie-wing provides immediate identification of the tooth for which the bracket was designed. Triple Chamfered Slot Walls Ease of engagement, reducing the chance of the archwire binding or crimping. Smooth Swept Tie Wings Helps reduce occlusal interference while increasing patient comfort.
http://www.eksenmedikal.com.tr/in-ovation-mini-small-imprint-big-impactIn-Ovation® R - The Original
In-Ovation R has been recognized as an industry leader for over a decade. Thousands of clinicians worldwide have trusted In-Ovation to treat their patients. The precision and quality built into these brackets offers repeatable success, practice efficiencies and beautiful results every time. See how far In-Ovation R can take you, your patients and your practice. In-Ovation Means Interactive In-Ovation R provides you with the ability to start and effectively finish your treatment with one, simple system. Using the technique of your choice, In-Ovation R enables you to maintain the precise degree of control that you need for each phase of your patient’s treatment. In-Ovation R’s unique Interactive technology means you can choose the degree of engagement between the bracket and wire. It can be passive for leveling and aligning, expressive where control is realized and free-sliding is maintained, or active for controlled, optimal finishing. Passive Phase Expressive Phase Active Phase Small, round wires slide freely, initiating the tooth movement process as the archwire gently levels the teeth and coaxes them into alignment. Square or rectangular wires are gently seated into the base of the slot without contacting the clip. Programming is expressed, rotations are corrected and space closures are completed. Rectangular archwires extend beyond the slot to fully engage the clip, providing the active control necessary for functional finishing, uprighting of the roots and adjusting the torque. Practice Advantages Not all self-ligating brackets are created equal. In-Ovation R brackets were created to optimize the treatment process with precision engineering and true straight wire design. The In-Ovation orthodontic systems are the result of a keen understanding of human physiology and orthodontic engineering. The compound contoured base of the In-Ovation R bracket is designed to provide a precise anatomical fit across the enamel surface of the tooth. The smooth swept tie-wings are engineered to minimize occlusal interference in order to increase patient comfort. In addition, the chamfered archwire slot is designed to reduce chair time by facilitating wire engagement and reducing the chance of archwire binding or crimping. This dedication to quality and attention to detail is infused into every product that carries the In-Ovation name. Patient Advantages Today more than ever, patients are doing their part to better understand the options available to them. Savvy practices have come to recognize this as an opportunity, enabling you to offer the benefits of self-ligation as an adjunct to your talent, technique and reputation. In providing a self-ligating option, you’ll be able to offer your patients less chair time, fewer appointments and a cleaner, more esthetic appearance. In doing so, you’ll be able to create a perceived (and potentially significant) point of differentiation between your practice and the other competing practices in the area. In-Ovation R Dedication to Detail True Twin Design – Occlusal and gingival twin tie-wings offer an optimal mesial, distal span for achieving superior rotation control. The elimination of the elastomeric ligatures increase your inter-bracket distance. Spring Clip – The self-ligating clip extends fully through the vertical channel in the bracket body, enhancing the structural integrity of the clip. Base Design – The exclusive patented Palmer Notation laser etched into the mesh facilitates bracket management with a ready reference of the quadrant, tooth and prescription.An 80 gauge single mesh, compound contoured base provides a precise anatomical fit. Full Slot Slip Coverage – The In-Ovation R clip provides full coverage across the entire slot for superior rotational control. This allows the clip to interact with the wire both on the mesial and distal, as needed, without the need for auxiliaries. Straight Wire Technology In-Ovation is a completely adjusted true straight wire appliance system that positions teeth at all four dimensions: in/out, angulations, torque, and overcorrection. With this completely adjusted four dimensional appliance system you will need no offset bends in the archwires to obtain an optimal finish in most cases (if the brackets are optimally positioned on teeth). In order to be considered a completely four-dimensional appliance, the bracket must contain: Compound contour base Torque in base Proper in/out and anti-rotation Level slot alignment at the conclusion of appliance therapy Easy Open Clip – The clip opens easily when pressure is applied occlusally to the v-notched clip at the gingival side of the bracket, using the engage R or similar instrument. The clip can be closed with an instrument or simple finger pressure on the incisal curve. Triple Chamfered Slot Walls – Slot walls are beveled outward, facilitating wire engagement and reducing the chance of the archwire binding or crimping. Vertical Scribe Line – A scribe line on the bracket face aids positioning by providing a convenient reference for orienting the center line of the bracket with the facial axis of the clinical crown (FACC). Smooth Swept Tie-Wings –Help to reduce occlusal interference while increasing patient comfort. Adequate undercuts allow easy anchoring for elastic chains or the fastening of color ties at the patient’s request.
http://www.eksenmedikal.com.tr/in-ovation-r-the-originalOPAL Crimpable Ball Hook
Precision manufactured split crimpable ball hooks offer reliable performance during treatment when elastics or extension springs are needed. Also provides an effective alternative to preposted arch wires. The ball hook may be crimped without removing the arch wire. Ball hook is straight and measures 5mm from base to ball. The straight hook may be bent in any direction. Fits round and rectangular wire sizes up to .021ʺ x .028ʺ.
http://www.eksenmedikal.com.tr/crimpable-ball-hookOPAL Nickel Titanium 15" Spooled Open-Coil Spring
Nickel Titanium 15" Spooled Open-Coil Spring
http://www.eksenmedikal.com.tr/nickel-titanium-15-spooled-open-coil-springG&H G4™ Nickel Titanium Closed Coil Springs - 21" Spools
Closed Coil Springs deliver ideal forces for Class II intra-arch maxillary retraction as well as other space closure and maintenance applications. .030” coil diameter - 21” spool The unique G4™ Nickel Titanium alloy developed by G&H® is precision formed into closed coil springs. G4™ Springs provide consistent force and remain active until the space is closed. Consistent force values and full recovery are both routinely achieved with G4™ NiTi Springs - and also G4™ NiTi Archwires.
http://www.eksenmedikal.com.tr/g-h-g4-nickel-titanium-closed-coil-springs-21-spoolsG&H G4™ Nickel Titanium Closed Coil Springs
G4™ Nickel Titanium Closed Coil Springs The unique G4™ Nickel Titanium alloy developed by G&H® is precision formed into closed coil springs. G4™ Springs provide consistent force and remain active until the space is closed. Consistent force values and full recovery are both routinely achieved with G4™ NiTi Springs - and also G4™ NiTi Archwires. Step 1. Use the specially designed Ruler to measure the distance between hooks. (Fig. A) Step 2. Flip the ruler over to view recommended spring for the 150g force range or refer to the Force Chart and select any force level and size spring desired. Step 3. Match the spring size desired to the label on the box and engage spring (Fig. B). Special OfferOrder 12 boxes or more of your choice of springs. Receive a box of measuring gauges, inventory kit box and a laminated force chart at no charge.(12 box minimum)
http://www.eksenmedikal.com.tr/g-h-g4-nickel-titanium-closed-coil-springsG&H G4™ Nickel Titanium Closed Coil TAD Springs
G4™ Nickel Titanium Closed Coil TAD Springs The unique G4™ Nickel Titanium alloy developed by G&H® is precision formed into closed coil springs. G4™ Springs provide consistent force and remain active until the space is closed. Consistent force values and full recovery are both routinely achieved with G4™ NiTi Springs - and also G4™ NiTi Archwires. Step 1. Use the specially designed TAD Ruler to measure the distance between the screw head and the hook. (Fig. A) Step 2. Flip the ruler over to view recommended spring for the 200g force range or refer to the Force Chart and select any force level and size spring desired. Step 3. Match the spring size desired to the label on the box and engage spring (Fig. B). The TAD eyelet is shaped to allow quick and easy engagement without ligation to virtually all TAD Screws. The G&H® design slips over the screw head then snaps in place locking positively on the neck. Special OfferOrder 12 boxes or more of your choice of springs. Receive a box of measuring gauges, inventory kit box and a laminated force chart at no charge.(12 box minimum)
http://www.eksenmedikal.com.tr/g-h-g4-nickel-titanium-closed-coil-tad-springsG&H G4™ Nickel Titanium Open Coil Springs - 15mm
G4™ Nickel Titanium Open Coil Springs - 15mm Open coil springs sized in 15mm lengths with inside diameter of .036 designed for opening spaces up to 15mm. Compresses to 3mm. Package of 10 springs The unique G4™ Nickel Titanium alloy developed by G&H® is precision formed into closed coil springs. G4™ Springs provide consistent force and remain active until the space is closed. Consistent force values and full recovery are both routinely achieved with G4™ NiTi Springs - and also G4™ NiTi Archwires.
http://www.eksenmedikal.com.tr/g-h-g4-nickel-titanium-open-coil-springs-15mmG&H G4™ Nickel Titanium Open Coil Springs
Open coil springs open and maintain space gently and efficiently in a convenient cut to length design.Choose from (3) 7" straight lengths or (1) 21" SpoolPrecision formed G4™ Nickel Titanium alloy into closed coil springs. G4™ Nickel Titaniam springs provide consistent force and remain active until the space is closed. Consistent force values and full recovery are both routinely achieved with G4™ Nickel Titanium. *Forces determined by compressing a 1" open coil spring. Wire Size I.D. Force Compressed 25% (.250") Compressed 50% (.500") .009" .030 Extra Light 95 g 225 g .010" .030 Light 120 g 260 g .010" .036 Medium Light 90 g 200 g .012" .030 Medium 220 g 480 g .012" .036 Medium Heavy 180 g 380 g .014" .030 Heavy 360 g 700 g .014" .036 Extra Heavy 270 g 560 g .010" .045 Facebow 50 g 120 g
http://www.eksenmedikal.com.tr/g-h-g4-nickel-titanium-open-coil-springsG&H 7" MOLAR DISTALIZING OPEN COIL SPRING .010x.045
Molar Distalizing Open Coil Springs deliver gentle 100 grams of force to achieve average 1mm to 1.5mm distalization per month without patient cooperation. Place over archwire and anchor with stop hook and elastics or Nance Appliance for maximum effectiveness. Intermittent closed coil sections allow for end stops when cut to length. .045" I.D.
http://www.eksenmedikal.com.tr/g-h-7-molar-distalizing-open-coil-spring-010x-045G&H SPRING, MOLAR DIST. 21" SPOOL
Molar Distalizing Open Coil Springs deliver gentle 100 grams of force to achieve average 1mm to 1.5mm distalization per month without patient cooperation. Place over archwire and anchor with stop hook and elastics or Nance Appliance for maximum effectiveness. Intermittent closed coil sections allow for end stops when cut to length. .045" I.D.
http://www.eksenmedikal.com.tr/g-h-spring-molar-dist-21-spoolG&H NITI SEP SPRINGS
NiTi Separating (Neet) Springs offer efficient force for separating contact points prior to banding. Simple engagement and self activating. .018" Wire Diameter.
http://www.eksenmedikal.com.tr/g-h-niti-sep-springsG&H SS CLOSED COIL SPR, 010x030
G&H open and closed coil springs are available on 21" spools. No eyelets.
http://www.eksenmedikal.com.tr/g-h-ss-closed-coil-spr-010x030G&H SS OPEN COIL SPR
G&H open and closed coil springs are available on 21" spools. No eyelets
http://www.eksenmedikal.com.tr/g-h-ss-open-coil-sprGAC Stop Wound Open Coil Spring
Sentalloy Stop Wound Open Coil Springs are packaged individually or in three 7” lengths to a tube. Each length is quadruple wound every 4mm. After determining the length of coil needed, simply cut the wire at the center of the tight spiral as indicated below: The quadruple wind can be cut by having one person stretch the wind while another person makes the cut; or by using a separating plier to stretch the wind and a hard wire cutter to make the cut. Sentalloy Stop Wound Open Coils with a standard lumen of .035” are available in forces of 50, 100, 150 and 200 grams. (.045” compatible coils are available in 150 grams of force only.)
http://www.eksenmedikal.com.tr/stop-wound-open-coil-springGAC Open Coil Spring
Open, or compression, coils are 15mm in length when passive and may be compressed to 3mm. Between these points, the coil will exert 50 (extra light), 100 (light), 150 (medium), 200 (heavy), or 250 (extra heavy) , and 300 (XX Heavy) grams of force until 14mm, and then the force falls to 0 as it becomes passive again. No distortion will occur during movement. These low forces limit patient discomfort and ensure good circulation in the periodontal pocket during movement. Typically, you will see 4mm of space opened in three months (this varies depending on the age and health of the patient). To engage the open coils, mark the archwire where the mesial and distal tooth destinations are located. Crimp on the mesial stop and ligate the archwire up to the point where the spring is to be placed. Slide the coil over the archwire and crimp on the distal stops. Ligate the balance of the wire. Since the Sentalloy coil needs about 1/10 as much wire as steel, good hygiene is much easier, but do advise the patient to rinse and brush around the coil. No other adjustment is needed.
http://www.eksenmedikal.com.tr/open-coil-springGAC Molar Distallization Coils
Maxillary molars can be moved distally in 4-7 months without patient cooperation using our 100 gram Stop Wound Open Coil Springs. A modified Nance or A.C.C.O. may be used as an anchorage device initially. The coils are placed between the 1st bicuspid and the 1st molar – by passing the 2nd bicuspid. The coils are then activated against the molar using an archwire lock or our special crimpable stop. Cut the Stop Wound Open Coils so that they extend to the end of the buccal tube. Ligate the archwire to the 1st bicuspid, set the stop, then slide the coil onto the archwire. Next, feed the archwire into the tube, ensuring that the archwire is fully inserted with 2mm of wire extending beyond the tube. Uprighting springs may be used from the 1st bicuspid to the distal of the laterals to control any anterior movement. Using this system, you will see 1mm per month in space gained, with any anchorage loss well within clinically acceptable limits.
http://www.eksenmedikal.com.tr/gac-molar-distallization-coilsGAC Sentalloy® Closed Coil Springs
Closing spaces with closed Sentalloy coil springs brings exceptional results. TWO DESIGNS ARE AVAILABLE: Two Eyelet Design: The initial length is 3mm unactivated (this does not include the eyelet lengths). These can be activated to 15mm without any deformation or change in force. No change in force will be seen as the coil contracts, reducing the space. To engage, slide over a molar hook and slowly stretch to the post on the cuspid bracket or a sliding hook on the archwire. Use a locking Mathieu plier on the widened platform of the eyelet. If you do not use the cuspid post, tie the archwire to the tooth you wish to move, slide on the sliding hook, then tie in the balance of the wire. Now engage the spring as above. For an eyelet with ligature wire, you have the option of hooking the eyelet on the molar, then activating the spring and tying it to the cuspid bracket with the .008” ligature wire. Should you wish to span an area greater than 15mm, measure the span first. Then place the coil on the molar hook and activate the coil 10mm. Tie the ligature wire to the bracket.
http://www.eksenmedikal.com.tr/gac-sentalloy-closed-coil-springsGAC Anterior Retracting Springs
Anterior Retracting Springs are available for segmented retraction of the maxillary four incisors. The increased force in these springs was designed to overcome the resistance of the roots and the rectangular archwire. Stops may be set on the archwire to ensure the proper destination. The eyelets are engaged from our crimped hook or an archwire lock to the molar hook. Expect 1mm of movement per month of activation.
http://www.eksenmedikal.com.tr/gac-anterior-retracting-springs